12.12.2012 Views

T-Series Climate Changer ® Air Handlers Sizes 3 through ... - Trane

T-Series Climate Changer ® Air Handlers Sizes 3 through ... - Trane

T-Series Climate Changer ® Air Handlers Sizes 3 through ... - Trane

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Removing <strong>Air</strong>borne Contaminants<br />

Effectively controlling particulate and<br />

gaseous contaminants by reducing<br />

their concentrations to acceptable<br />

levels or removing them from the<br />

airstream altogether is another key to<br />

ensuring good indoor air quality. That<br />

necessitates proper filter selection.<br />

<strong>Trane</strong>’s T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> <strong>®</strong> air<br />

handler can be equipped with a variety<br />

of filtration options:<br />

• pleated media with 20- to 95-percent<br />

efficiency (ASHRAE Standard 52-1976)<br />

• bag or cartridge filters with 65- to 95<br />

percent efficiency (ASHRAE Standard<br />

52-1976)<br />

• antimicrobial-treated filters<br />

Recovering Energy<br />

Increased ventilation airflow increases<br />

heating and cooling loads, and<br />

ultimately, operating costs. Bringing in<br />

more fresh air when outdoor<br />

temperatures are low also increases<br />

the risk of damaging coils. <strong>Air</strong>side<br />

energy recovery addresses both<br />

concerns by salvaging heat from the<br />

exhaust airstream to precondition<br />

outdoor air entering the building. A coil<br />

runaround loop may be used in<br />

conjunction with other <strong>Trane</strong> products<br />

to achieve a more energy-efficient air<br />

handling system. See your local <strong>Trane</strong><br />

sales engineer for more details.<br />

<strong>Trane</strong> offers a wide variety of filtration<br />

options for the T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />

handler.<br />

Features<br />

and<br />

Benefits<br />

Providing Quiet Comfort<br />

Acceptable space sound levels<br />

enhance occupant comfort and<br />

productivity. However, system designs<br />

that promote good IAQ can adversely<br />

affect acoustics: unlined ductwork, air<br />

handlers with solid double-wall<br />

construction, and increased fan static<br />

pressures (resulting from the addition<br />

of energy recovery and increased<br />

filtration) can magnify the building’s<br />

background sound.<br />

Controlling noise at its source is the<br />

most cost-effective solution for<br />

providing quiet comfort in the space.<br />

This “source attenuation” can<br />

eliminate the need for duct-mounted<br />

silencers and thereby lower fan<br />

operating costs (by reducing system<br />

static pressure). But to control source<br />

noise, you must choose:<br />

• The right fan – FC, BI, AF, plug or<br />

Model Q <br />

• The right casing construction – use<br />

solid or perforated double-wall<br />

• The right unit configuration – possibly<br />

add an inlet or discharge plenum<br />

All of the above choices should be<br />

based on AMCA 300 tested data and a<br />

working knowledge of acoustics. <strong>Trane</strong><br />

has the tools (such as the <strong>Trane</strong><br />

Acoustics Program [TAP ]) and<br />

expertise to help with your acousticallysensitive<br />

jobs. Consult your local <strong>Trane</strong><br />

engineer for assistance.<br />

9<br />

Total Quality for a Total<br />

Solution<br />

The T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />

handler combines comprehensive<br />

performance certification by the <strong>Air</strong><br />

Conditioning and Refrigeration Institute<br />

(ARI) with thorough laboratory testing<br />

and advanced manufacturing methods.<br />

Together, these elements help assure<br />

that each T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />

handler operates predictably and<br />

reliably <strong>through</strong>out its life. Unlike other<br />

rating methods that check fan<br />

performance alone, T-<strong>Series</strong> <strong>Climate</strong><br />

<strong>Changer</strong>s are performance-tested in<br />

accordance with ARI Standard 430 in a<br />

certification process that evaluates the<br />

entire air handler on the basis of<br />

airflow, static pressure, fan speed and<br />

brake horsepower. Heating and cooling<br />

coils are rigorously tested in<br />

compliance with ARI Standard 410 to<br />

assure that they also deliver cataloged<br />

performance.<br />

The T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />

handler and its standard options are<br />

listed by Underwriters Laboratories Inc.<br />

This product has been evaluated by UL<br />

and meets the applicable U.S. and<br />

Canadian safety standards.<br />

Modifications to the TSC may affect UL<br />

Listing. Consult your local <strong>Trane</strong> office<br />

for further information.<br />

Our state-of-the-art manufacturing<br />

facility employs a system of “Total<br />

Quality Checks” and verifications at<br />

each work station to ensure consistent<br />

high quality. And <strong>through</strong> the use of<br />

Demand Flow Technology (DFT) in<br />

our manufacturing facilities, we can<br />

better serve you by providing greater<br />

product flexibility, ever improving<br />

product quality and shorter<br />

manufacturing cycles.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!