Removing <strong>Air</strong>borne Contaminants<br />
Effectively controlling particulate and<br />
gaseous contaminants by reducing<br />
their concentrations to acceptable<br />
levels or removing them from the<br />
airstream altogether is another key to<br />
ensuring good indoor air quality. That<br />
necessitates proper filter selection.<br />
<strong>Trane</strong>’s T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> <strong>®</strong> air<br />
handler can be equipped with a variety<br />
of filtration options:<br />
• pleated media with 20- to 95-percent<br />
efficiency (ASHRAE Standard 52-1976)<br />
• bag or cartridge filters with 65- to 95<br />
percent efficiency (ASHRAE Standard<br />
52-1976)<br />
• antimicrobial-treated filters<br />
Recovering Energy<br />
Increased ventilation airflow increases<br />
heating and cooling loads, and<br />
ultimately, operating costs. Bringing in<br />
more fresh air when outdoor<br />
temperatures are low also increases<br />
the risk of damaging coils. <strong>Air</strong>side<br />
energy recovery addresses both<br />
concerns by salvaging heat from the<br />
exhaust airstream to precondition<br />
outdoor air entering the building. A coil<br />
runaround loop may be used in<br />
conjunction with other <strong>Trane</strong> products<br />
to achieve a more energy-efficient air<br />
handling system. See your local <strong>Trane</strong><br />
sales engineer for more details.<br />
<strong>Trane</strong> offers a wide variety of filtration<br />
options for the T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />
handler.<br />
Features<br />
and<br />
Benefits<br />
Providing Quiet Comfort<br />
Acceptable space sound levels<br />
enhance occupant comfort and<br />
productivity. However, system designs<br />
that promote good IAQ can adversely<br />
affect acoustics: unlined ductwork, air<br />
handlers with solid double-wall<br />
construction, and increased fan static<br />
pressures (resulting from the addition<br />
of energy recovery and increased<br />
filtration) can magnify the building’s<br />
background sound.<br />
Controlling noise at its source is the<br />
most cost-effective solution for<br />
providing quiet comfort in the space.<br />
This “source attenuation” can<br />
eliminate the need for duct-mounted<br />
silencers and thereby lower fan<br />
operating costs (by reducing system<br />
static pressure). But to control source<br />
noise, you must choose:<br />
• The right fan – FC, BI, AF, plug or<br />
Model Q <br />
• The right casing construction – use<br />
solid or perforated double-wall<br />
• The right unit configuration – possibly<br />
add an inlet or discharge plenum<br />
All of the above choices should be<br />
based on AMCA 300 tested data and a<br />
working knowledge of acoustics. <strong>Trane</strong><br />
has the tools (such as the <strong>Trane</strong><br />
Acoustics Program [TAP ]) and<br />
expertise to help with your acousticallysensitive<br />
jobs. Consult your local <strong>Trane</strong><br />
engineer for assistance.<br />
9<br />
Total Quality for a Total<br />
Solution<br />
The T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />
handler combines comprehensive<br />
performance certification by the <strong>Air</strong><br />
Conditioning and Refrigeration Institute<br />
(ARI) with thorough laboratory testing<br />
and advanced manufacturing methods.<br />
Together, these elements help assure<br />
that each T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />
handler operates predictably and<br />
reliably <strong>through</strong>out its life. Unlike other<br />
rating methods that check fan<br />
performance alone, T-<strong>Series</strong> <strong>Climate</strong><br />
<strong>Changer</strong>s are performance-tested in<br />
accordance with ARI Standard 430 in a<br />
certification process that evaluates the<br />
entire air handler on the basis of<br />
airflow, static pressure, fan speed and<br />
brake horsepower. Heating and cooling<br />
coils are rigorously tested in<br />
compliance with ARI Standard 410 to<br />
assure that they also deliver cataloged<br />
performance.<br />
The T-<strong>Series</strong> <strong>Climate</strong> <strong>Changer</strong> air<br />
handler and its standard options are<br />
listed by Underwriters Laboratories Inc.<br />
This product has been evaluated by UL<br />
and meets the applicable U.S. and<br />
Canadian safety standards.<br />
Modifications to the TSC may affect UL<br />
Listing. Consult your local <strong>Trane</strong> office<br />
for further information.<br />
Our state-of-the-art manufacturing<br />
facility employs a system of “Total<br />
Quality Checks” and verifications at<br />
each work station to ensure consistent<br />
high quality. And <strong>through</strong> the use of<br />
Demand Flow Technology (DFT) in<br />
our manufacturing facilities, we can<br />
better serve you by providing greater<br />
product flexibility, ever improving<br />
product quality and shorter<br />
manufacturing cycles.