Table GD-3: General Data —Air Handlers<br />

<strong>System</strong> Data<br />

No. Refrigerant Circuits<br />

Suction Line (in.) OD<br />

Liquid Line (in.) OD<br />

Indoor Coil -Type<br />

Tube Size (in.)<br />

Face Area (sq. ft.)<br />

Rows/FPI<br />

Refrigerant Control<br />

Drain Connection Size (in.)<br />

Indoor Fan - Type<br />

No. Used/Diameter x Width (in.)<br />

Drive Type/No. Speeds<br />

CFM<br />

No. Motors<br />

Motor HP - Standard/Oversized<br />

Motor RPM<br />

Motor Frame Size<br />

Filters - Type/Furnished<br />

(No.)/Size Recommended<br />

Single Circuit<br />

TWE060A1,A3,A4,AW<br />

1<br />

1 1/8<br />

3/8<br />

Plate Fin<br />

.375<br />

5.0<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/12 x 12<br />

Belt/Adjustable<br />

2000<br />

1<br />

.75/1.00<br />

1725<br />

56<br />

Throwaway/Yes<br />

(1) 16 x 20 x 1<br />

(1) 20 x 20 x 1<br />

General Data<br />

Air Handlers<br />

ARI tested and certified with various heat pumps per ARI Standard 210/240 or 340/360 or 365-00 certification program. Refer to performance data section in<br />

this catalog.<br />

Notes:<br />

1 Ships wired for 208-230/60/3. Field convertible to 460/60/3.<br />

2 TWE060A1 has motor RPM of 3450 for oversized motor.<br />

3 TWE120A1 does not have an oversized motor option.<br />

Table GD-3: General Data —Air Handlers (continued)<br />

<strong>System</strong> Data<br />

No. Refrigerant Circuits<br />

Suction Line (in.) OD<br />

Liquid Line (in.) OD<br />

Indoor Coil -Type<br />

Tube Size (in.)<br />

Face Area (sq. ft.)<br />

Rows/FPI<br />

Refrigerant Control<br />

Drain Connection Size (in.)<br />

Indoor Fan - Type<br />

No. Used/Diameter x Width (in.)<br />

Drive Type/No. Speeds<br />

CFM<br />

No. Motors<br />

Motor HP - Standard/Oversized<br />

Motor RPM<br />

Motor Frame Size<br />

Filters - Type/Furnished<br />

(No.)/Size Recommended<br />

Dual Circuit<br />

TWE120B1,B3 1<br />

2<br />

1 1/8<br />

3/8<br />

Plate Fin<br />

.375<br />

11.2<br />

4/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

4000<br />

1<br />

2.00/-<br />

1725<br />

56HZ<br />

Throwaway/Yes<br />

(4) 16 x 25 x 1<br />

5 Ton 7 1/2 Ton 10 Ton<br />

Dual Circuit<br />

TWE060B1,B3,B4<br />

2<br />

3/4<br />

5/16<br />

Plate Fin<br />

.375<br />

5.0<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/12 x 12<br />

Belt/Adjustable<br />

2000<br />

1<br />

.75/1.00<br />

1725<br />

56<br />

Throwaway/Yes<br />

(1) 16 x 20 x 1<br />

(1) 20 x 20 x 1<br />

Single Circuit<br />

TWE090A1,A3 1 ,AW<br />

1<br />

1 3/8<br />

1/2<br />

Plate Fin<br />

.375<br />

8.1<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

3000<br />

1<br />

1.50/2.00<br />

1725<br />

56H<br />

Throwaway/Yes<br />

(3) 16 x 25 x 1<br />

Dual Circuit<br />

TWE090B1,B3 1<br />

2<br />

1 1/8<br />

3/8<br />

Plate Fin<br />

.375<br />

8.1<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

3000<br />

1<br />

1.50/2.00<br />

1725<br />

56H<br />

Throwaway/Yes<br />

(3) 16 x 25 x 1<br />

Single Circuit<br />

TWE0120A1<br />

Single Circuit<br />

TWE120A3 1 ,AW<br />

ARI tested and certified with various heat pumps per ARI Standard 210/240 or 340/360 or 365-00 certification program. Refer to performance data section in<br />

this catalog.<br />

Notes:<br />

1 Ships wired for 208-230/60/3. Field convertible to 460/60/3<br />

2 Coil has filter rack as standard, but no filters. When using this coil as a duct coil, use below size recommended. Filters for coil not recommended when<br />

using coil with upflow gas furnaces.<br />

SS-PRC002-EN 13<br />

1<br />

1 3/8<br />

1/2<br />

Plate Fin<br />

.375<br />

11.2<br />

4/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

4000<br />

1<br />

2.00/3.00<br />

1725<br />

56HZ<br />

Throwaway/Yes<br />

(4) 16 x 25 x 1<br />

10 Ton 15 Ton 20 Ton<br />

Dual Circuit<br />

TWE120BW<br />

2<br />

1 1/8<br />

3/8<br />

Plate Fin<br />

.375<br />

11.2<br />

4/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

4000<br />

1<br />

2.00/3.00<br />

1725<br />

56HZ<br />

Throwaway/Yes<br />

(4) 16 x 25 x 1<br />

Dual Circuit<br />

TXE120B500B<br />

2<br />

1 1/8<br />

3/8<br />

Plate Fin<br />

.375<br />

11.2<br />

4/12<br />

Expansion Valve<br />

1 PVC<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

Throwaway/No 2<br />

(4) 16 x 25 x 1<br />

Dual Circuit<br />

TWE180B3,B4,BW<br />

2<br />

1 3/8<br />

1/2<br />

Plate Fin<br />

.375<br />

16.3<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

2/15 x 15<br />

Belt/Adjustable<br />

6000<br />

1<br />

3.00/5.00<br />

1735/1750<br />

145T<br />

Throwaway/Yes<br />

(8) 15 x 20 x 2<br />

Dual Circuit<br />

TWE240B3,B4,BW<br />

2<br />

1 3/8<br />

1/2<br />

Plate Fin<br />

.375<br />

21.6<br />

3/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

2/15 x 15<br />

Belt/Adjustable<br />

8000<br />

1<br />

5.00/7.50<br />

1750/3470<br />

184T<br />

Throwaway/Yes<br />

(4) 16 x 25 x 2<br />

(4) 16 x 20 x 2<br />

1<br />

1 3/8<br />

1/2<br />

Plate Fin<br />

.375<br />

11.2<br />

4/12<br />

Expansion Valve<br />

1 PVC<br />

Centrifugal<br />

1/15 x 15<br />

Belt/Adjustable<br />

4000<br />

1<br />

2.00/3.00<br />

1725<br />

56HZ<br />

Throwaway/Yes<br />

(4) 16 x 25 x 1