Table PD-3: Gross <strong>Cooling</strong> Capacities (MBh) 10 Ton TTA120A Condensing Unit with 10 Ton TWE120A Air Handler<br />

CFM<br />

Airflow<br />

Enter.<br />

DB<br />

(° F)<br />

Ambient Temperature<br />

85 95 105 115<br />

Entering WB<br />

61 67 73 61 67 73 61 67 73 61 67 73<br />

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC<br />

3600 75 117.7 91.3 129.9 77.1 143.5 52.5 113.3 89.0 125.4 75.2 138.4 50.8 108.8 86.7 120.5 73.3 133.1 48.9 104.0 84.3 115.3 71.2 127.4 47.0<br />

80 118.1 105.8 130.3 87.6 143.5 68.3 114.0 103.7 125.8 85.6 138.5 66.4 109.6 101.5 120.9 83.6 133.2 64.4 105.0 99.2 115.8 81.4 127.6 62.3<br />

85 119.6 119.6 130.4 102.4 143.8 83.5 116.2 116.2 125.9 100.4 138.8 81.6 112.5 112.5 121.1 98.2 133.5 79.6 108.6 108.6 116.0 95.9 127.9 77.5<br />

90 125.6 125.6 131.0 117.2 144.0 98.6 122.1 122.1 126.6 115.2 139.1 96.7 118.4 118.4 122.0 113.1 133.8 94.7 114.4 114.4 117.1 110.9 128.3 92.7<br />

4000 75 119.9 95.2 132.4 75.0 145.9 53.6 115.6 93.0 127.7 73.0 140.8 51.8 111.0 90.7 122.7 70.9 135.2 49.9 106.0 88.3 117.4 68.7 129.4 47.8<br />

80 120.8 111.3 132.8 91.5 146.0 70.4 116.6 109.2 128.1 89.5 140.9 68.5 112.2 107.0 123.1 87.4 135.4 66.5 107.4 104.7 117.8 85.2 129.6 64.4<br />

85 123.5 123.5 132.9 107.5 146.3 87.0 120.0 120.0 128.2 105.4 141.2 85.1 116.2 116.2 123.3 103.2 135.8 83.1 112.1 112.1 118.0 100.9 130.0 81.0<br />

90 129.9 129.9 133.9 123.7 146.6 103.5 126.2 126.2 129.4 121.7 141.5 101.6 122.3 122.3 124.7 119.5 136.1 99.6 118.1 118.1 119.7 117.3 130.1 97.0<br />

4400 75 121.9 99.0 134.5 77.3 148.0 54.6 117.5 96.8 129.6 75.3 142.7 52.7 112.7 94.5 124.5 73.2 137.0 50.6 107.6 92.1 119.0 71.0 130.9 48.5<br />

80 123.1 116.6 134.8 95.2 148.1 72.5 118.9 114.5 130.0 93.1 142.8 70.6 114.4 112.3 124.8 91.0 137.2 68.5 108.9 108.9 119.2 88.4 131.3 66.4<br />

85 127.0 127.0 135.0 112.3 148.4 90.4 123.4 123.4 130.2 110.2 143.2 88.4 119.4 119.4 125.2 108.0 137.6 86.4 115.1 115.1 119.9 105.7 131.7 84.3<br />

90 133.6 133.6 136.4 129.9 148.7 108.2 129.7 129.7 131.9 127.9 143.3 105.8 125.7 125.7 127.1 125.8 137.7 103.7 121.3 121.3 121.4 121.4 131.9 101.4<br />

4800 75 123.6 102.7 136.2 79.6 149.7 55.3 119.1 100.5 131.2 77.6 144.2 53.3 114.3 98.2 126.0 75.5 138.4 51.3 109.2 95.7 120.4 73.2 132.2 49.1<br />

80 125.2 121.6 136.5 98.7 149.9 74.4 121.0 119.5 131.4 96.3 144.5 72.5 115.7 115.7 126.2 94.0 138.7 70.5 111.4 111.4 120.7 91.7 132.7 68.3<br />

85 130.2 130.2 136.9 116.9 150.2 93.6 126.3 126.3 132.0 114.8 144.8 91.6 122.2 122.2 127.0 112.6 139.1 89.6 117.8 117.8 121.6 110.3 133.1 87.5<br />

90 136.9 136.9 138.8 136.0 150.3 112.2 132.9 132.9 134.2 133.9 145.0 110.1 128.7 128.7 128.8 128.8 139.3 108.0 124.1 124.1 124.3 124.3 133.3 105.7<br />

Equal MBH and SHC values constitute dry coil condition. Total Gross <strong>Cooling</strong> Capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat<br />

Capacity (SHC) is the total capacity.<br />

All capacities shown are gross and have not considered indoor fan heat.<br />

To obtain net cooling capacities, subtract indoor fan heat.<br />

MBH = Total Gross <strong>Cooling</strong> Capacity<br />

SHC = Sensible Heat Capacity<br />

Table PD-4: Gross <strong>Cooling</strong> Capacities (MBh) 10 Ton TTA120B Condensing Unit with 10 Ton TWE120B Air Handler<br />

CFM<br />

Airflow<br />

Enter.<br />

DB<br />

(° F)<br />

Ambient Temperature<br />

85 95 105 115<br />

Entering WB<br />

61 67 73 61 67 73 61 67 73 61 67 73<br />

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC<br />

3600 75 114.9 89.9 127.2 76.2 140.5 52.0 111.2 88.0 123.1 74.5 135.7 50.3 107.3 86.0 118.5 72.7 130.2 48.5 103.1 83.8 113.6 70.7 124.1 46.2<br />

80 115.6 104.7 127.9 87.2 141.1 68.0 112.0 102.8 123.8 85.5 136.5 66.2 108.2 100.8 118.9 82.9 131.3 64.3 104.1 98.7 114.0 80.7 125.4 62.1<br />

85 117.8 117.8 128.2 101.6 141.8 83.4 114.7 114.7 124.2 99.7 137.2 81.6 111.5 111.5 119.7 97.6 132.1 79.7 107.9 107.9 114.8 95.4 126.3 77.5<br />

90 124.0 124.0 129.0 116.5 142.3 98.7 120.9 120.9 125.0 114.6 137.4 96.4 117.4 117.4 120.7 112.6 132.3 94.3 113.6 113.6 115.9 110.3 126.6 91.9<br />

4000 75 117.3 93.9 129.8 74.5 142.8 52.9 113.5 92.0 125.5 72.7 137.7 51.2 109.4 89.9 120.7 70.7 132.1 49.3 105.0 87.7 115.6 68.6 125.7 47.1<br />

80 118.3 110.2 130.0 90.6 143.7 70.2 114.6 108.2 125.8 88.7 138.9 68.5 110.6 106.2 121.1 86.5 133.5 66.5 106.4 104.0 116.0 84.2 127.3 64.2<br />

85 121.8 121.8 130.8 106.7 144.4 87.0 118.6 118.6 126.6 104.7 139.7 85.3 115.1 115.1 121.9 102.6 134.4 83.3 111.2 111.2 116.8 100.2 128.3 81.0<br />

90 128.3 128.3 131.9 123.0 144.6 102.9 125.0 125.0 127.9 121.1 140.0 101.0 121.4 121.4 123.4 119.0 134.7 98.9 117.2 117.2 118.4 116.7 128.7 96.4<br />

4400 75 119.3 97.7 131.8 76.9 144.5 53.9 115.3 95.7 127.4 75.1 139.4 52.1 111.2 93.6 122.5 73.1 133.6 50.2 106.6 91.3 117.1 70.9 127.0 47.9<br />

80 120.6 115.4 132.2 94.1 145.8 72.3 116.9 113.4 127.8 92.1 140.9 70.5 112.9 111.4 123.0 89.9 135.3 68.5 108.0 108.0 117.7 87.5 128.9 66.3<br />

85 125.3 125.3 133.0 111.4 146.6 90.5 122.0 122.0 128.7 109.5 141.8 88.7 118.3 118.3 123.9 107.3 136.2 86.7 114.2 114.2 118.6 104.9 129.5 83.4<br />

90 132.1 132.1 134.5 129.2 146.9 107.4 128.7 128.7 130.4 127.3 142.2 105.5 124.8 124.8 125.9 125.2 136.7 103.2 120.4 120.4 120.5 120.5 130.5 100.7<br />

4800 75 121.0 101.4 133.6 79.2 146.1 54.8 117.0 99.3 129.0 77.4 140.9 52.9 112.7 97.2 124.0 75.3 134.9 50.8 108.0 94.8 117.8 72.3 128.1 48.5<br />

80 122.8 120.4 134.1 97.4 147.6 74.3 119.0 118.5 129.6 95.4 142.6 72.5 114.5 114.5 124.6 93.2 136.8 70.5 110.4 110.4 119.1 90.7 130.3 68.2<br />

85 128.5 128.5 134.9 116.0 148.4 93.7 125.0 125.0 130.5 114.1 143.0 91.2 121.1 121.1 125.6 111.8 137.4 88.9 116.7 116.7 120.2 109.4 131.0 86.3<br />

90 135.5 135.5 137.0 135.2 148.8 111.6 131.9 131.9 132.0 132.0 144.0 109.7 127.8 127.8 127.9 127.9 138.4 107.4 123.2 123.2 123.3 123.3 132.0 104.9<br />

Equal MBH and SHC values constitute dry coil condition. Total Gross <strong>Cooling</strong> Capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat<br />

Capacity (SHC) is the total capacity.<br />

All capacities shown are gross and have not considered indoor fan heat.<br />

To obtain net cooling capacities, subtract indoor fan heat.<br />

MBH = Total Gross <strong>Cooling</strong> Capacity<br />

SHC = Sensible Heat Capacity<br />

Performance Data<br />

10 Tons<br />

SS-PRC002-EN 15