Technical Details – Components for Fluorescent Lamps<br />

Mechanical mounting<br />

Surface<br />

Solid, flat surface for good heat dissipation required.<br />

Avoid mounting on protruding surfaces.<br />

Mounting location<br />

Electronic ballasts must be protected against moisture and heat.<br />

Installation in external luminaires: water protection rate of ≥ 4<br />

(e.g. IP54 required)<br />

Fastening<br />

Heat transfer<br />

With M4 screws in the designated holes<br />

If the ballast is destined for installation in a luminaire, sufficient heat transfer must be<br />

ensured between the ballast and the luminaire casing.<br />

Electronic ballasts should be mounted with the greatest possible clearance to heat sources<br />

or lamps. During operation, the temperature measured at the t c point of the ballast<br />

must not exceed the specified maximum value.<br />

Supplement for independent electronic ballasts<br />

Mounting position Any<br />

Clearance<br />

Surface<br />

Min. of 0.10 m from walls, ceilings, insulation<br />

Min. of 0.10 m from other electronic ballasts<br />

Min. of 0.25 m from sources of heat (lamp)<br />

Solid; device must not be allowed to sink into insulation materials<br />

Technical specifications<br />

Operating voltage range<br />

AC: 220 to 240 V (±10%)<br />

DC: please observe the specifications on the individual product pages<br />

Ignition time<br />

Preheat time<br />

Leak current<br />

ELXe ballasts t < 0.5 seconds (instant start)<br />

ELXc and ELXd ballasts t = 0.5 or 1.5 to 2.5 seconds (warm start)<br />

≤ 0.5 mA per electronic ballast<br />

Product features<br />

Overheating<br />

<strong>VS</strong> EBs for fluorescent lamps are not protected against overheating<br />

Overvoltage protection<br />

AC: up to 48 hours at UNAC = 320 V<br />

DC: no disorders occur with input voltages of up to UNDC 285 V.<br />

UNDC voltages in excess of 288 V destroy the ballast.<br />

Shutdown of defective lamps<br />

During starting operation, the electronic ballast will detect whether a lamp is connected.<br />

If no lamp is present, the ballast will cancel the starting operation. Deactivated lamps or<br />

interrupted electrodes are detected and lead to the high-frequency supply being<br />

switched off after an unsuccessful ignition attempt. Changing a lamp during operation<br />

will lead to the high-frequency supply being switched off.<br />