27.12.2012 Views

VRV IV sets the standard …again - Daikin

VRV IV sets the standard …again - Daikin

VRV IV sets the standard …again - Daikin

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Round flow cassette<br />

Round flow cassette:<br />

setting <strong>the</strong> <strong>standard</strong><br />

for efficiency and comfort<br />

The round flow cassette is designed for use in all<br />

forms and sizes of commercial offices & retail<br />

environments. Today, <strong>Daikin</strong> has improved its<br />

technology even fur<strong>the</strong>r to enhance your comfort<br />

and provide you better energy efficient models.<br />

Even more energy efficient…<br />

… and improved comfort<br />

• With <strong>the</strong> optional infrared floor sensor having cold feet will<br />

become history. This sensor detects <strong>the</strong> average floor<br />

temperature and ensures even temperature distribution<br />

between ceiling and floor.<br />

104<br />

presence sensor<br />

floor sensor<br />

• With <strong>the</strong> optional infrared presence sensor <strong>the</strong> set point can be adjusted or <strong>the</strong> round flow cassette switched off when <strong>the</strong>re is nobody<br />

in <strong>the</strong> room. Up to 27% energy can be saved (estimated) with this new function. If no presence is detected in <strong>the</strong> room for 15mins,<br />

<strong>the</strong> set temperature is changed until a minimum temperature (for heating) or maximum temperature (for cooling) is reached.<br />

When selecting <strong>the</strong> setback function, <strong>the</strong> unit will maintain <strong>the</strong> temperature within a preset minimum and maximum temperature,<br />

when <strong>the</strong>re is no presence detected in <strong>the</strong> room for 1 hour.<br />

inside temperature (°CDB)<br />

Without sensor<br />

time<br />

26°<br />

24°<br />

22°<br />

20°<br />

09.00<br />

Nobody in<br />

<strong>the</strong> room<br />

Flexible installation<br />

09.30<br />

10.00<br />

10.30<br />

11.00<br />

11.30<br />

12.00<br />

12.30<br />

13.00<br />

13.30<br />

14.00<br />

14.30<br />

15.00<br />

15.30<br />

• The presence sensor directs air flow<br />

away from any person detected in <strong>the</strong><br />

room, when <strong>the</strong> air flow control is on.<br />

• The unique 360° airflow discharge<br />

pattern ensures a uniform temperature<br />

distribution across <strong>the</strong> room without<br />

dead corners.<br />

Cooling<br />

Set point: 22° CDB<br />

16.00<br />

16.30<br />

17.00<br />

• When refurbishing or rearranging <strong>the</strong> interior of your office, shop<br />

or o<strong>the</strong>r area, you no longer need to change <strong>the</strong> location of your<br />

indoor unit. With <strong>the</strong> round flow cassette one or more flaps can<br />

be easily closed via <strong>the</strong> wired remote controller (BRC1E52A/B<br />

– optional). Optional closure kits are available as well.<br />

With sensor (BRC1E52A/B required)<br />

inside temperature (°CDB)<br />

time<br />

26°<br />

24°<br />

22°<br />

20°<br />

no presence detected for 15mins<br />

• <strong>Daikin</strong> was <strong>the</strong> first to launch an auto-cleaning decoration<br />

panel. With this panel <strong>the</strong> costs can be fur<strong>the</strong>r reduced<br />

as <strong>the</strong> filter cleans itself automatically once a day. Up to<br />

50% energy can be saved thanks to daily filter cleaning.<br />

Energy consumption (kWh)<br />

9000<br />

8000<br />

7000<br />

6000<br />

5000<br />

4000<br />

3000<br />

2000<br />

1000<br />

0<br />

09.00<br />

Cumulative energy comparison over 12 months<br />

July<br />

August<br />

September<br />

October<br />

Nobody in<br />

<strong>the</strong> room<br />

09.30<br />

10.00<br />

10.30<br />

11.00<br />

11.30<br />

12.00<br />

12.30<br />

13.00<br />

13.30<br />

14.00<br />

14.30<br />

15.00<br />

15.30<br />

(Test site, Wolverhampton, UK)<br />

�<br />

November<br />

December<br />

January<br />

February<br />

March<br />

April<br />

50% difference<br />

in electricity<br />

consumption<br />

May<br />

June<br />

16.00<br />

16.30<br />

17.00<br />

Auto cleaning cassette Standard round flow cassette<br />

July

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!