27.12.2012 Views

VRV IV sets the standard …again - Daikin

VRV IV sets the standard …again - Daikin

VRV IV sets the standard …again - Daikin

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EKRTR / EKRTW<br />

› Easy and convenient regulation of <strong>the</strong> indoor temperature,<br />

resulting in ideal comfort and energy efficiency<br />

› Heating and cooling mode, with possibility to<br />

disable cooling mode if not required<br />

› Comfort function mode activates <strong>the</strong> programmed temperature levels<br />

intended for a home occupied during <strong>the</strong> day; default setpoints are 21°C in<br />

heating mode and 24°C in cooling mode and can be changed by <strong>the</strong> user<br />

› Reduced function mode activates <strong>the</strong> programmed temperature levels for<br />

periods when <strong>the</strong> house is unoccupied or at night; default setpoints are<br />

17°C in heating, 28°C in cooling mode and can be changed by <strong>the</strong> user<br />

› Scheduled function mode: uses a timer to schedule heating<br />

and cooling setpoints throughout <strong>the</strong> day; up to 12 setpoints<br />

can be programmed per day; <strong>the</strong> selected setpoints will<br />

be automatically activated at <strong>the</strong> scheduled time<br />

› Holiday function mode: intended for setting reduced and fuelefficient<br />

setpoints when <strong>the</strong> house is unoccupied for long periods.<br />

The default setpoints are 14°C for heating and 30°C for cooling.<br />

› Off function: switches <strong>the</strong> system off; however, <strong>the</strong> integrated<br />

frost protection remains activated (set by default at 4°C).<br />

› Setpoint limitation <strong>sets</strong> <strong>the</strong> upper and lower setpoint limits<br />

within which <strong>the</strong> user can programme <strong>the</strong> desired comfort<br />

levels and can only be modified by <strong>the</strong> installer<br />

› Number of setpoint changes: 12/day<br />

› Key lock function: possible to lock <strong>the</strong> keys of <strong>the</strong> room <strong>the</strong>rmostat<br />

Wired room <strong>the</strong>rmostat<br />

Dimensions Unit HeightxWidthxDepth mm<br />

Weight Unit g<br />

Ambient<br />

Storage Min./Max. °C<br />

temperature Operation Min./Max. °C<br />

Temperature<br />

setting range<br />

Wireless room <strong>the</strong>rmostat<br />

Dimensions Thermostat Height/Width/Depth mm<br />

Receiver Height/Width/Depth mm<br />

Weight Thermostat g<br />

Receiver g<br />

Ambient<br />

Storage Min./Max. °C<br />

temperature Operation Min./Max. °C<br />

Temperature<br />

setting range<br />

EKRTR<br />

Heating Min./Max. °C<br />

Cooling Min./Max. °C<br />

Clock Yes<br />

Regulation function Proportional band<br />

Power supply Voltage V Battery powered 3* AA-LR6 (alkaline)<br />

Connection Type Wired<br />

Heating Min./Max. °C<br />

Cooling Min./Max. °C<br />

EKRTW<br />

35<br />

Wireless and wired room <strong>the</strong>rmostat<br />

EKRTWA<br />

87x125x34<br />

215<br />

-20/60<br />

0/50<br />

4/37<br />

4/37<br />

EKRTR1<br />

87/125/34<br />

170/50/28<br />

210<br />

125<br />

-20/60<br />

0/50<br />

4/37<br />

4/37<br />

Clock Yes<br />

Regulation function Proportional band<br />

Power supply Thermostat Voltage V Battery powered 3x AA-LRG (alkaline)<br />

Receiver Voltage V<br />

230<br />

Frequency Hz<br />

50<br />

Phase<br />

1~<br />

Connection Thermostat Wireless<br />

Receiver Wired<br />

Maximum distance Indoor m approx.30m<br />

to receiver Outdoor m approx.100m