VRV IV sets the standard …again - Daikin
VRV IV sets the standard …again - Daikin
VRV IV sets the standard …again - Daikin
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
EHVH-C / ERLQ-CV3/CW1<br />
EHVH-C ERLQ004-008CV3 ER(L/H)Q011-016CV3/BV3<br />
› Integrated indoor unit: all-in-one fl oor standing heat<br />
pump unit including <strong>the</strong> domestic hot water tank<br />
› Energy effi cient heating only system based on<br />
air to water heat pump technology<br />
› Perfect fi t for new built as well as for low energy houses<br />
› Best seasonal effi ciencies, providing <strong>the</strong> highest savings on running costs<br />
› Flexible confi guration with respect to heat emitters<br />
› Outdoor unit extracts heat from <strong>the</strong> outdoor air, even at -25°C<br />
› Inverter controlled swing compressor<br />
Heating only<br />
22<br />
<strong>Daikin</strong> Al<strong>the</strong>rma low temperature split<br />
Space heating<br />
Domestic hot<br />
water<br />
Indoor unit<br />
EHVH04S18C3V EHVH08S18C3V EHVH08S26C9W EHVH16S18C3V EHVH16S26C9W<br />
Casing Colour White White<br />
Material Precoated sheet metal Precoated sheet metal<br />
Dimensions Unit HeightxWidthxDepth mm<br />
1,732x600x728 1,732x600x728<br />
Weight Unit kg<br />
115 116 126 120 129<br />
Operation range Heating Ambient Min.~Max. °C<br />
-25~25 -25~25 -25~35<br />
Water side Min.~Max. °C<br />
15~55 15~55<br />
Domestic hot Ambient Min.~Max. °CDB<br />
-25~35 -20~35<br />
water<br />
Water side Min.~Max. °C<br />
25~60 25~60<br />
Sound power level Nom. dBA<br />
42 47<br />
Sound pressure level Nom. dBA<br />
28 33<br />
BE/31/001<br />
down to<br />
-25°C<br />
Outdoor unit<br />
ERLQ004CV3 ERLQ006CV3 ERLQ008CV3 ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1<br />
Heating capacity Min. kW<br />
1.80<br />
Nom. kW<br />
Max. kW<br />
Power input Heating Nom. kW<br />
COP<br />
Dimensions Unit HeightxWidthxDepth mm<br />
Weight Unit kg<br />
Operation range Heating Min.~Max. °CWB<br />
Domestic hot water Min.~Max. °CDB<br />
Refrigerant Type<br />
Charge kg<br />
Sound power level Heating Nom. dBA<br />
Sound pressure level Heating Nom. dBA<br />
Power supply Name/Phase/Frequency/Voltage Hz/V<br />
Current Recommended fuses A<br />
(1) cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) - (2) cooling Ta 35°C - LWE 18--7°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)<br />
1 / 1.802 1.801 / 1.802 1.801 / 1.802 -<br />
4.401 / 4.032 6.001 / 5.672 7.401 / 6.892 11.38 14.55 16.10<br />
5.121 / 4.902 8.351 / 7.952 10.021 / 9.352 -<br />
0.871 / 1.132 1.271 / 1.592 1.661 / 2.012 2.64 3.43 3.83<br />
5.041 / 3.582 4.741 / 3.562 4.451 / 3.422 4.31 4.24 4.20<br />
735x832x307 1,345x900x320<br />
54 56 113 /114<br />
-25~25 -25~35<br />
-25~35 -20~35<br />
R-410A R-410A<br />
1.45 1.60 3.4<br />
61 62 64 66<br />
48 49 51 52<br />
V3/1~/50/230 V3/1~/50/230 // W1/3N~/50/400<br />
20 40/20