RWEYQ-PR<br />
RWEYQ-PR<br />
› Reduced CO 2 emmisions thanks to <strong>the</strong> use of geo<strong>the</strong>rmal<br />
energy as a renewable energy source<br />
› No need for an external heating or cooling source<br />
› Extended operation range (inlet water<br />
temperature) down to -10°C in heating<br />
› High heating efficiency at low water entering temperatures (eg.<br />
3.44 COP at -10°C entering water temperature for an 8HP unit)<br />
› Suitable for multi-storey and large buildings because of<br />
<strong>the</strong> hardly unlimited possibilities of water piping<br />
› Simultaneous cooling and heating operation from one system<br />
› ‘High sensible mode’: allows <strong>the</strong> <strong>VRV</strong> system to work with<br />
increased sensible capacity in cooling mode, resulting<br />
in higher efficiency and improved comfort<br />
› 2-stage heat recovery: first stage between indoor units, second stage<br />
between outdoor units thanks to <strong>the</strong> storage of energy in <strong>the</strong> water circuit<br />
› Heat recovery systems offer <strong>the</strong> highest comfort, including individual<br />
change-over of each BS box without disruption of o<strong>the</strong>r BS boxes<br />
› Wide range of indoor units: 15 different models in a total of 76 variations<br />
› Compact design (stacked configuration possible)<br />
› Connectable to current <strong>Daikin</strong> control systems: DS-net, Intelligent<br />
Touch Controller, Intelligent Manager, BACnet Gateway, DMS-iF<br />
Heat recovery<br />
Heating & Cooling<br />
(1) In case of heat pump system, gas pipe is not used (2) In case of heat recovery system (3) In case of heat pump system<br />
69<br />
<strong>VRV</strong>III water cooled, geo<strong>the</strong>rmal series<br />
Heat pump operation<br />
Outdoor unit<br />
RWEYQ8PR RWEYQ10PR<br />
Capacity range HP<br />
8 10<br />
Cooling capacity Nom. kW<br />
22.4 26.1<br />
Heating capacity Nom. kW<br />
25.0 31.5<br />
Power input - 50Hz Cooling Nom. kW<br />
4.58 6.30<br />
Heating Nom. kW<br />
4.30 6.20<br />
EER<br />
4.89 4.14<br />
COP<br />
5.81 5.08<br />
Maximum number of connectable indoor units<br />
17 21<br />
Indoor index Min.<br />
100 125<br />
connection Nom.<br />
200 250<br />
Max.<br />
200 250<br />
Dimensions Unit HeightxWidthxDepth mm<br />
1,000x780x550<br />
Weight Unit kg<br />
149 150<br />
Sound power level Cooling Nom. dBA<br />
-<br />
Sound pressure level Cooling Nom. dBA<br />
50 51<br />
Operation range Inlet water Cooling Min.~Max. °CDB<br />
6~45<br />
temperature Heating Min.~Max. °CWB<br />
-10~45<br />
Refrigerant Type R-410A<br />
Piping<br />
Liquid OD mm<br />
9.52<br />
connections Gas OD mm<br />
19.1 (1) 22.2 (1)<br />
Discharge gas OD mm<br />
15.9 (2) / 19.1 (3) 19.1 (2) / 22.2 (3)<br />
Water Inlet/Outlet PT1 1/4B internal thread/PT1 1/4B internal thread<br />
Piping length OU - IU Max. m<br />
120<br />
Total piping length System Actual m<br />
300<br />
Level difference OU - IU m 50 (outdoor unit in highest position) / 40 (indoor unit in highest position)<br />
Power supply Phase/Frequency/Voltage Hz/V<br />
3~/50/380-415<br />
Current - 50Hz Maximum fuse amps (MFA) A<br />
25