EKHWP-B<br />
EKHWP-B<br />
› Domestic hot water at any time thanks to large hot water storage<br />
› Heat loss is reduced to a minimum thanks to <strong>the</strong> high quality insulation<br />
› Better performance with unpressurised solar system both<br />
for low temperature and high temperature solutions<br />
› For latest information, see page 349<br />
44<br />
Domestic hot water tank<br />
Domestic hot water tank<br />
*EKHWP300B *EKHWP500B<br />
Casing Colour Dust grey (RAL7037)<br />
Material Impact resistant polypropylene<br />
Dimensions Unit HeightxWidthxDepth mm<br />
1,590x595x615 1,590x790x790<br />
Weight Unit Empty kg<br />
59 92<br />
Tank Water volume l<br />
300 500<br />
Maximum water temperature °C<br />
85<br />
Heat exchanger Domestic hot Tube material Stainless steel (DIN 1.4404)<br />
water<br />
Face area m²<br />
5.7 5.9<br />
Internal coil volume l<br />
27.8 28.4<br />
Operating pressure bar<br />
6<br />
Average specific<br />
<strong>the</strong>rmal output<br />
W/K<br />
2,795 2,860<br />
Charging Tube material Stainless steel (DIN 1.4404)<br />
Face area m²<br />
2.5 3.7<br />
Internal coil volume l<br />
12.3 17.4<br />
Average specific<br />
<strong>the</strong>rmal output<br />
W/K<br />
1,235 1,809<br />
Auxiliary solar Tube material Stainless steel (DIN 1.4404)<br />
heating Face area m²<br />
- 1.0<br />
Internal coil volume l<br />
- 5<br />
Average specific<br />
<strong>the</strong>rmal output<br />
W/K<br />
- 313<br />
*Note: grey cells contain preliminary data