Multi model applications<br />

MXS<br />

INSTALLATION FLEXIBILITY<br />

A very wide range is available, from 2-port to 5-port units,<br />

making all applications possible. Up to 5 indoor units can be<br />

connected to 1 multi outdoor unit. All indoor units can be<br />

individually controlled with remote control and do not need<br />

to be installed in <strong>the</strong> same room or even at <strong>the</strong> same time. The<br />

outdoor units are neat and sturdy and can be mounted easily<br />

on a roof or terrace or simply placed against an outside wall;<br />

WIDE CHOICE<br />

It is possible to combine different types of indoor units:<br />

wall mounted, fl oor standing, round fl ow cassette, ceiling<br />

suspended, fl exi type, concealed ceiling, 4-way blow cassette<br />

Outdoor multi split units are fitted with <strong>the</strong> <strong>Daikin</strong> swing<br />

compressor, renowned for its low noise and high energy<br />

efficiency.<br />

5MXS90E<br />

95<br />

RXYSQ<br />

INSTALLATION FLEXIBILITY<br />

Up to 9 indoor units can be connected to 1 multi outdoor unit.<br />

All indoor units can be individually controlled with remote<br />

control and do not need to be installed in <strong>the</strong> same room<br />

or even at <strong>the</strong> same time. Narrow refrigerant piping makes<br />

handling and connecting easier, resulting in significantly<br />

reduced installation time. The REFNET joint reduces <strong>the</strong> amount<br />

of work involved in installation and increases <strong>the</strong> reliability of<br />

<strong>the</strong> system. A maximum total piping length of 145m offers<br />

much more flexibility in <strong>the</strong> choice of installation position for<br />

<strong>the</strong> indoor units and greatly simplifies system planning. The<br />

Branch Provider (BP) unit varies <strong>the</strong> refrigerant volume to meet<br />

<strong>the</strong> cooling or heating requirements of a room.<br />

WIDE CHOICE<br />

It is possible to combine different types of indoor units:<br />

wall mounted, fl oor standing, round fl ow cassette, ceiling<br />

suspended, fl exi type, concealed ceiling.<br />

BP<br />

BP<br />

BP Refnet<br />

RXYSQ-P8V1