VAM-FA/FB<br />

Total heat exchanged<br />

foul air<br />

Clean outdoor air<br />

› Energy saving ventilation by recovery of indoor unit heat/cold<br />

› Ideal solution for shops, restaurants or offices requiring<br />

maximum floor space for furniture, decorations and fittings<br />

› Free cooling when outdoor temperature is below<br />

indoor temperature (eg. during night time)<br />

› Low energy consumption thanks to DC inverter fans<br />

› Prevent energy losses from over-ventilation while maintaining<br />

indoor air quality with CO sensor (optional)<br />

› Can be used as stand alone unit or integrated in <strong>the</strong> <strong>VRV</strong> system<br />

› Wide range of units: air flow rate from 150 up to 2,000 m³/h<br />

› High efficiency filters available in F6 ,F7, F8 grades<br />

› Specially developed heat exchange element<br />

with High Efficiency Paper (HEP)<br />

› No drain piping needed<br />

› Can operate in over- and under pressure<br />

› For latest information, see page 349<br />

Ventilation<br />

Power input - 50Hz Heat exchange mode Nom. Ultra high kW<br />

Bypass mode Nom. Ultra high kW<br />

Temperature exchange efficiency - 50Hz Ultra high %<br />

Enthalpy exchange Cooling Ultra high %<br />

efficiency - 50Hz Heating Ultra high %<br />

Operation mode Heat exchange mode / Bypass mode / Fresh-up mode Heat exchange mode / Bypass mode / Fresh-up mode<br />

Heat exchange system Air to air cross flow total heat (sensible + latent heat) exchange Air to air cross flow total heat (sensible + latent heat) exchange<br />

Heat exchange element Specially processed non-flammable paper Specially processed non-flammable paper<br />

Dimensions Unit HeightxWidthxDepth mm<br />

Weight Unit kg<br />

Fan-Air flow rate Heat exchange mode Ultra high m³/h<br />

- 50Hz<br />

Bypass mode Ultra high m³/h<br />

Fan-External static pressure - 50Hz Ultra high Pa<br />

Sound pressure Heat exchange mode Ultra high dBA<br />

level - 50Hz Bypass mode Ultra high dBA<br />

Operation range Min. °CDB<br />

Max. °CDB<br />

Relative humidity %<br />

Connection duct diameter mm<br />

Power supply Phase/Frequency/Voltage Hz/V<br />

Current Maximum fuse amps (MFA) A<br />

Foul indoor air<br />

Total heat<br />

exchanged<br />

clean air<br />

186<br />

Heat reclaim ventilation<br />

VAM150FA VAM250FA *VAM350FB *VAM500FB *VAM650FB *VAM800FB *VAM1000FB *VAM1500FB *VAM2000FB<br />

0.116 0.141 -<br />

0.116 0.141 -<br />

74 72 75 74 74 74 75 75 75<br />

58 61 58 58 60 61 61 61<br />

64 65 62 63 65 66 66 66<br />

285x776x525 301x828x816 364x1,004x868 364x1,004x1,156 726x1,514x868<br />

24 33 33 48 48 61 132 158<br />

150 250 350 500 650 800 1,000 1,500 2,000<br />

150 250 350 500 650 800 1,000 1,500 2,000<br />

69 64 98 98 93 137 157 137 137<br />

27 / 28.5 28 / 29 32 / 34 33 / 34.5 34.5 / 35.5 36 / 37 36 / 37 39.5 / 41.5 40 / 42.5<br />

27 / 28.5 28 / 29 32 / 34 33.5 / 34.5 34.5 / 35.5 36 / 37 36 / 37 40.5 / 41.5 40 / 42.5<br />

-15 -15<br />

50 50<br />

80% or less 80% or less<br />

100 150 200 250 350<br />

1~/50/60/220-240/220 1~/50/60/220-240/220<br />

15 15<br />