REYAQ-P<br />
› Temperature control, fresh air provision, Biddle air curtains and<br />
hot water production all integrated in a single system<br />
› Heat recovery maximises energy efficiency with COPs of up to 8 possible!<br />
› Free heating provided by transferring heat from areas<br />
requiring cooling to areas requiring heating or hot water<br />
› Perfect comfort: simultaneous heating and cooling<br />
› Compact size leaves maximum floorspace<br />
› Fits any building with ei<strong>the</strong>r outdoor or indoor installation<br />
possible (high external static pressure up to 78.4Pa)<br />
› The ability to control each conditioned zone individually keeps<br />
<strong>VRV</strong> system running costs to an absolute minimum<br />
› Spread your installation cost by phased installation<br />
› Wide range of indoor units: 15 different models in a total of 76 variations<br />
Heat recovery<br />
(1) Field setting<br />
REYAQ-P<br />
<strong>VRV</strong>III heat recovery, with connection to heating<br />
only hydrobox<br />
Outdoor unit<br />
REYAQ10P REYAQ12P REYAQ14P REYAQ16P<br />
Capacity range HP<br />
10 12 14 16<br />
Cooling capacity Nom. kW<br />
28 33.5 40 45<br />
Heating capacity Nom. kW<br />
31.5 37.5 45 50<br />
Power input - 50Hz Cooling Nom. kW<br />
7.09 8.72 11.4 14.1<br />
Heating Nom. kW<br />
7.38 8.84 11.0 12.8<br />
EER<br />
3.95 3.84 3.51 3.19<br />
COP<br />
4.27 4.24 4.09 3.91<br />
Maximum number of connectable indoor units<br />
21 26 30 34<br />
Indoor index Min.<br />
125 150 175200 connection Nom.<br />
250 300 350 400<br />
Max.<br />
325 390 455 520<br />
Dimensions Unit HeightxWidthxDepth mm<br />
1,680x1,300x765<br />
Weight Unit kg<br />
331 339<br />
Sound power level Cooling Nom. dBA<br />
78 80 83 84<br />
Sound pressure level Cooling Nom. dBA<br />
58 60 62 63<br />
Operation range Cooling Min.~Max. °CDB<br />
-5~43<br />
Heating Min.~Max. °CWB<br />
-20~15.5<br />
Hot water<br />
Space heating Min.~Max. °CDB<br />
-20~20 / 24 (1) -20~20 / 24 (1) -20~20 / 24 (1) -20~20 / 24 (1)<br />
production<br />
Domestic hot water Min.~Max. °CDB<br />
-20~43<br />
Refrigerant Type R-410A<br />
Piping<br />
Liquid OD mm<br />
9.52 12.7<br />
connections Gas OD mm<br />
22.2 28.6<br />
Discharge gas OD mm<br />
19.1 22.2<br />
Piping length OU - IU Max. m<br />
100<br />
Total piping length System Actual m<br />
300<br />
Level difference OU - IU m 40 (outdoor unit in highest position) / 40 (indoor unit in highest position)<br />
Power supply Phase/Frequency/Voltage Hz/V<br />
3~/50/380-415<br />
Current - 50Hz Maximum fuse amps (MFA) A<br />
25 40<br />
151