EHVH-C /<br />
ERHQ-BV3/BW1<br />
Heating only<br />
23<br />
<strong>Daikin</strong> Al<strong>the</strong>rma low temperature split<br />
Indoor unit<br />
EHVH16S18C3V EHVH16S26C9W EHVH16S18C3V EHVH16S26C9W<br />
Casing Colour White White<br />
Material Precoated sheet metal Precoated sheet metal<br />
Dimensions Unit HeightxWidthxDepth mm<br />
Weight Unit kg<br />
Operation range Heating Ambient Min.~Max. °C<br />
Water side Min.~Max. °C<br />
Domestic hot<br />
water<br />
Ambient Min.~Max. °CDB<br />
Water side Min.~Max. °C<br />
Sound power level Nom. dBA<br />
Sound pressure level Nom. dBA<br />
Outdoor unit<br />
Heating capacity Nom. kW<br />
Power input<br />
COP<br />
Heating Nom. kW<br />
Dimensions Unit HeightxWidthxDepth mm<br />
Weight Unit kg<br />
Operation range Heating Min.~Max. °CWB<br />
Domestic hot water Min.~Max. °CDB<br />
Refrigerant Type<br />
Charge kg<br />
Sound power level Heating Nom. dBA<br />
Sound pressure level Heating Nom. dBA<br />
Power supply Name/Phase/Frequency/Voltage Hz/V<br />
Current Recommended fuses A<br />
down to<br />
-20°C<br />
1,732x600x728 1,732x600x728<br />
120 129 120 129<br />
-25~35 -25~35<br />
15~55 15~55<br />
-20~35 -20~35<br />
25~60 25~60<br />
47 47<br />
33 33<br />
ERHQ011BV3 ERHQ014BV3 ERHQ016BV3 ERHQ011BW1 ERHQ014BW1 ERHQ016BW1<br />
11.2 14.0 16.0 11.32 14.50 16.05<br />
2.55 3.26 3.92 2.63 3.42 3.82<br />
4.39 4.29 4.08 4.30 4.24 4.20<br />
1,170x900x320 1,345x900x320<br />
103 108<br />
-20~35 -20~35<br />
-20~43 -20~43<br />
R-410A R-410A<br />
3.7 2.95<br />
- 64 66<br />
49 51 53 51 52<br />
V3/1~/50/230 W1/3N~/50/400<br />
32 20