TECHNICAL INFORMATION<br />

Characteristic values for injection anchor XV Plus<br />

Loads for injection system VMU Plus with anchor rods VMU-A/IG/VM-A, galvanised, A4<br />

and HCR for masonry in accordance with European Technical Assessment ETA-13/0909.<br />

Characteristic values for perforated blocks with perforated sleeve<br />

Anchor rods: Steel ≥ FKL 5.8, A4, HCR ≥ FKL 70 M8 M10 M12 IG-M8<br />

Perforated sleeves: VM-SH 12 x 80 16 x 85 20 x 85 20 x 85<br />

Ventilated lime sand block KSL-12DF acc. to <strong>EN</strong> 771-2, bulk density: 1.4 kg/dm 3 , minimum format: 498 x 175 x 238 mm (e.g. Wemding)<br />

Anchoring depth hef mm 80 85 85 85<br />

Axial spacing parallel to horizontal joint scr,II mm 498 498 498 498<br />

Axial spacing vertical to horizontal joint scr,_I_ mm 238 238 238 238<br />

Minimum axial spacing smin mm 120 120 120 120<br />

Edge spacing ccr mm 100 100 120 120<br />

Minimum edge spacing cmin mm 100 100 120 120<br />

Minimum component thickness (masonry) hmin mm 115 115 115 115<br />

Permissible tensile load<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

Type MKT injection system VMU Plus for perforated blocks with perforated sleeve<br />

fb ≥ 10 N/mm 2 perm. N kN 0.17 0.17 0.43 0.43<br />

fb ≥ 12 N/mm 2 perm. N kN 0.21 0.21 0.43 0.43<br />

fb ≥ 16 N/mm 2 perm. N kN 0.26 0.26 0.57 0.57<br />

fb ≥ 10 N/mm 2 perm. V kN 0.71 1.57 1.57 1.57<br />

fb ≥ 12 N/mm 2 perm. V kN 0.86 1.86 1.86 1.86<br />

fb ≥ 16 N/mm 2 perm. V kN 1.00 2.29 2.29 2.29<br />

Perforated block of lightweight concrete Bloc creux B40 acc. to <strong>EN</strong> 771-3, bulk density: 0.8 kg/dm 3 , minimum format: 494 x 200 x 190 mm (e.g. Sepa)<br />

Anchoring depth hef mm 80 85 85 85<br />

Axial spacing parallel to horizontal joint scr,II mm 494 494 494 494<br />

Axial spacing vertical to horizontal joint scr,_I_ mm 190 190 190 190<br />

Minimum axial spacing smin mm 100 100 100 100<br />

Edge spacing ccr mm 100 100 120 120<br />

Minimum edge spacing cmin mm 100 100 120 120<br />

Minimum component thickness (masonry) hmin mm 115 115 115 115<br />

Permissible tensile load fb ≥ 4 N/mm 2 perm. N kN 0.34 0.34 0.34 0.34<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

fb ≥ 4 N/mm 2 perm. V kN 0.86 0.86 0.86 0.86<br />

Permissible loads without the effects of axial and edge spacing to component edges.<br />

Vertical and horizontal joints are mortared. The safety coefficient in accordance with ETAG is included (γM and γF).<br />

Temperature range +24 °C/+40 °C − use category dry/dry.<br />

Installation and plug characteristic values<br />

Characteristic values for perforated blocks with perforated sleeve<br />

Anchor rods: Steel ≥ FKL 5.8, A4, HCR ≥ FKL 70 M8 M10 M12 IG-M8<br />

Perforated sleeves: VM-SH 12 x 80 16 x 85 20 x 85 20 x 85<br />

Drilled hole diameter do mm 12 16 20 20<br />

Drilled hole depth ho mm 85 90 90 90<br />

Clearance hole in the add-on part df ≤ mm 9 12 14 9<br />

Brush diameter db ≥ mm 14 18 22 22<br />

Torque when anchoring Tinst,max Nm 2 2 2 2<br />

Amount of mortar per drill hole ml 11.2 24.9 41.1 41.1<br />

Drill holes per cartridge VMU Plus 280 piece 21 9 5 5<br />

Drill holes per cartridge VMU Plus 345 piece 27 12 7 7<br />

Drilling method<br />

rotary drilling<br />

07/<strong>2023</strong><br />

8/18 © Müpro - progress and quality