TECHNICAL INFORMATION<br />

Characteristic values for injection anchor XV Plus<br />

Loads for injection system VMU Plus with anchor rods VMU-A/IG/VM-A, galvanised, A4<br />

and HCR for masonry in accordance with European Technical Assessment ETA-13/0909.<br />

Characteristic values for solid blocks without perforated sleeve 1)<br />

Anchor rods 1) : Steel ≥ FKL 5.8, A4, HCR ≥ FKL 70 M8 M10 M12 IG-M8<br />

Building bricks Mz-DF acc. to <strong>EN</strong> 771-1, bulk density: 1.6 kg/dm 3 , minimum format: 240 x 115 x 55 mm (e.g. Unipor)<br />

Anchoring depth hef mm 80 90 100 100<br />

Axial spacing scr mm 240 270 300 300<br />

Minimum axial spacing smin mm 120 120 120 120<br />

Edge spacing ccr mm 120 135 150 150<br />

Minimum edge spacing cmin mm 60 60 60 60<br />

Minimum component thickness (masonry) hmin mm 110 120 130 130<br />

Permissible tensile load<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

fb ≥ 10 N/mm 2 perm. N kN 1.00 1.00 1.14 1.14<br />

fb ≥ 20 N/mm 2 perm. N kN 1.29 1.57 1.71 1.71<br />

fb ≥ 28 N/mm 2 perm. N kN 1.57 1.71 1.94 1.94<br />

fb ≥ 10 N/mm 2 perm. V kN 1.00 1.00 1.00 1.00<br />

fb ≥ 20 N/mm 2 perm. V kN 1.43 1.43 1.43 1.43<br />

fb ≥ 28 N/mm 2 perm. V kN 1.57 1.57 1.57 1.57<br />

Lime-sand brick KS-NF acc. to <strong>EN</strong> 771-2, bulk density: 2.0 kg/dm 3 , minimum format: 240 x 115 x 71 mm (e.g. Wemding)<br />

Anchoring depth hef mm 80 90 100 100<br />

Axial spacing scr mm 240 270 300 300<br />

Minimum axial spacing smin mm 120 120 120 120<br />

Edge spacing ccr mm 120 135 150 150<br />

Minimum edge spacing cmin mm 60 60 60 60<br />

Minimum component thickness (masonry) hmin mm 110 120 130 130<br />

Permissible tensile load<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

Type MKT injection system VMU Plus for solid blocks without perforated sleeve<br />

fb ≥ 10 N/mm 2 perm. N kN 1.29 1.29 1.29 1.29<br />

fb ≥ 20 N/mm 2 perm. N kN 1.71 1.71 1.71 1.71<br />

fb ≥ 27 N/mm 2 perm. N kN 2.00 2.00 2.00 2.00<br />

fb ≥ 10 N/mm 2 perm. V kN 0.71 0.86 0.71 0.71<br />

fb ≥ 20 N/mm 2 perm. V kN 1.14 1.29 1.14 1.14<br />

fb ≥ 27 N/mm 2 perm. V kN 1.29 1.57 1.29 1.29<br />

Solid block of lightweight concrete LAC acc. to <strong>EN</strong> 771-3, bulk density: 0.6 kg/dm 3 , minimum format: 300 x 123 x 248 mm (e.g. Bisotherm)<br />

Anchoring depth hef mm 80 90 100 100<br />

Axial spacing scr mm 240 270 300 300<br />

Minimum axial spacing smin mm 120 120 120 120<br />

Edge spacing ccr mm 120 135 150 150<br />

Minimum edge spacing cmin mm 60 60 60 60<br />

Minimum component thickness (masonry) hmin mm 110 120 130 130<br />

Permissible tensile load fb ≥ 6 N/mm 2 perm. N kN 0.86 0.86 1.00 1.00<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

fb ≥ 6 N/mm 2 perm. V kN 0.86 0.86 0.86 0.86<br />

1)<br />

Anchoring with perforated sleeve is permitted; technical data, see European Technical Assessment ETA-13/0909.<br />

Permissible loads without the effects of axial and edge spacing to component edges.<br />

Vertical and horizontal joints are mortared. The safety coefficient in accordance with ETAG is included (γM and γF).<br />

Temperature range +24 °C/+40 °C − use category dry/dry.<br />