TECHNICAL INFORMATION<br />

Characteristic values for injection anchor XV Plus<br />

Type MKT injection system VMU Plus solid blocks without perforated sleeve<br />

Loads for injection system VMU Plus with anchor rods VMU-A/IG/VM-A, galvanised, A4<br />

and HCR for masonry in accordance with European Technical Assessment ETA-13/0909<br />

Characteristic values for solid blocks without perforated sleeve 1)<br />

Anchor rods 1) : Steel ≥ FKL 5.8, A4, HCR ≥ FKL 70 M8 M10 M12 IG-M8<br />

Aerated concrete AAC6 acc. to <strong>EN</strong> 771-4, bulk density: 0.6 kg/dm 3 , minimum format: 499 x 240 x 249 mm (e.g. Porit)<br />

Anchoring depth hef mm 80 90 100 100<br />

Axial spacing scr mm 240 270 300 300<br />

Minimum axial spacing smin mm 100 100 100 100<br />

Edge spacing ccr mm 120 135 150 150<br />

cmin,N mm 75 75 75 75<br />

Minimum edge spacing<br />

cmin,v,II 2) mm 75 75 75 75<br />

cmin,v,_I_ 3) mm 120 135 150 150<br />

Minimum component thickness (masonry) hmin mm 110 120 130 130<br />

Permissible tensile load fb ≥ 2 N/mm 2 perm. N kN 0.89 1.43 1.79 1.79<br />

for compressive strength<br />

Permissible transverse load<br />

for compressive strength<br />

fb ≥ 2 N/mm 2 perm. V kN 2.14 3.57 3.57 3.57<br />

1)<br />

Anchoring with perforated sleeve is permitted; technical data, see European Technical Assessment ETA-13/0909.<br />

2)<br />

Minimum edge spacing Cmin,v,ll for transverse load parallel to free edge.<br />

3)<br />

Minimum edge spacing Cmin,v,_l_ for transverse load vertical to free edge.<br />

Permissible loads without the effects of axial and edge spacing to component edges.<br />

Vertical and horizontal joints are mortared. The safety coefficient in accordance with ETAG is included (γM and γF).<br />

Temperature range +24 °C/+40 °C − use category dry/dry.<br />

Installation and plug characteristic values<br />

Characteristic values for solid blocks without perforated sleeve<br />

Anchor rods 1) : Steel ≥ FKL 5.8, A4, HCR ≥ FKL 70 M8 M10 M12 IG-M8<br />

Drilled hole diameter do mm 10 12 14 14<br />

Drilled hole depth ho mm 80 90 100 100<br />

Clearance hole in the add-on part df ≤ mm 9 12 14 9<br />

Brush diameter db ≥ mm 12 14 16 16<br />

Torque when anchoring Tinst,max Nm 2 (14 for building bricks Mz-DF)<br />

Amount of mortar per drill hole ml 4.1 6.6 10 10<br />

Drill holes per cartridge VMU Plus 280 piece 58 36 24 24<br />

Drill holes per cartridge VMU Plus 345 piece 74 46 30 30<br />

1)<br />

Anchoring with perforated sleeve is permitted; technical data, see European Technical Assessment ETA-13/0909.<br />

07/<strong>2023</strong><br />

8/20 © Müpro - progress and quality