Process I/O<br />
ET 200M distributed I/O<br />
Power supply<br />
■ Overview<br />
■ Selection <strong>and</strong> Ordering Data Order No.<br />
The PS 307 or PS 305 load power supply is used to supply power PS 307 Load Power Supply<br />
to the ET 200M. There is a choice of input voltages <strong>and</strong> output Including connection assembly;<br />
currents (AC 120/230 V with 2 A, 5 A or 10 A, or DC 24...110 V<br />
with 2 A) to suit the field of application.<br />
120/230 V AC; 24 V DC<br />
- 2 A; 50 mm wide 6ES7 307-1BA00-0AA0<br />
- 5 A; 80 mm wide 6ES7 307-1EA00-0AA0<br />
- 5 A, extended temperature<br />
range; 80 mm wide<br />
6ES7 307-1EA80-0AA0<br />
- 10A, 200mm wide<br />
PS 305 Load Power Supply<br />
Including connection assembly;<br />
24/48/60/110 V DC; 24 V DC<br />
6ES7 307-1KA01-0AA0<br />
- 2 A, extended temperature<br />
range; 80 mm wide<br />
6ES7 305-1BA80-0AA0<br />
Interface module<br />
■ Overview<br />
■ Selection <strong>and</strong> Ordering Data Order No.<br />
An IM 153-2 High Feature interface module is needed to connect IM 153-2 High Feature<br />
6ES7 153-2BA00-0XB0 B)<br />
the ET 200M to the PROFIBUS DP field bus. It supports the fol- Slave interface module for conlowing<br />
functions:<br />
nection of an ET 200M to<br />
7 HART configuring of intelligent field devices,<br />
PROFIBUS DP, with time stamp<br />
(accuracy 5 ms), support of<br />
7 configuration of ET 200M I/Os in RUN mode of the automation HART functionality, F modules,<br />
system,<br />
7 connection to redundant AS 414H / AS 417H automation systems,<br />
7 use of ET 200M function modules (controller <strong>and</strong> counter modules).<br />
FM modules, "Configuration in<br />
RUN" function; also for use in<br />
redundant systems<br />
IM 153-2 FO High Feature<br />
Slave interface module for connection<br />
of an ET 200M to optical<br />
6ES7 153-2BB00-0XB0 B)<br />
This interface module is also available in a fiberoptic (FO) version<br />
for connecting to an optical PROFIBUS.<br />
PROFIBUS DP; support of HART<br />
functionality, F modules, FM modules,<br />
"Configuration in RUN" function;<br />
also for use in redundant<br />
systems<br />
Notes:<br />
Plastic fiberoptic cables <strong>and</strong> a mounting set for simplex connectors<br />
are required for use of the IM 153-2 FO (see "Plastic fiberoptic<br />
cables“ in the section "Communication/PROFI-<br />
BUS“)<br />
The active bus modules <strong>and</strong> the profile rail for hot swapping are<br />
required in order to be able to use the hot swapping function.<br />
B) Subject to export regulations: AL: N, ECCN: EAR99H<br />