Mounting / <strong>Installation</strong><br />
4.2.5 General <strong>Instruction</strong>s for the Gas Connection<br />
• The gas connection must be connected in accordance with the current<br />
regulations. <strong>Installation</strong> may only be performed by a licensed professional!<br />
• Make sure there is no open fire, flammable materials or the like in close<br />
proximity to the installation location. LIFE THREATENING DANGER!<br />
• Before installation, check to make sure the gas meter has adequate<br />
capacity. Take the usage of all household appliances into account.<br />
Let your energy provider know if your line does not have a high<br />
enough capacity.<br />
• Make sure the gas lines are clean. Clean the gas lines with high pressure<br />
or by knocking them clean before installation.<br />
• An approved shut-off valve with a fire protective faucet must be installed<br />
in front of the boiler.<br />
• Preferably, you can also install a gas filter to keep the gas control<br />
valve from getting dirty.<br />
4.2.6 Connecting the Gas Main<br />
Please follow these instructions during installation:<br />
• The main gas spigot must be shut off before the work begins. If the<br />
connection is older, make sure the spigot still closes to avoid uncontrolled<br />
gas leaking out.<br />
• Secure the line against accidental start up while you are working on<br />
the lines.<br />
• Make sure the fire protective faucet is mounted properly.<br />
• Before start up, make sure the entire gas line is sealed, especially at<br />
connection points. The gas faucet <strong>and</strong> the gas line may not exceed a<br />
maximum pressure of 150 mbar.<br />
• Ventilate the gas line after attaching to avoid malfunctions!<br />
• Ventilate the room well after installation to disperse any gas that may<br />
have escaped.<br />
- 17 -<br />