<strong>Operating</strong> the Controls<br />

6.3.5.2 Anti-Cycling Drinking-Water Heater<br />

When the dem<strong>and</strong> for drinking-water is over, the anti-cycling function is activated.<br />

When in this mode, the following information will be displayed<br />

Display Display Element<br />

Drinking-Water Temperature Segment B <strong>and</strong> C<br />

Celsius-Symbol Segment D<br />

Drinking-Water Heater Anti-Cycling LED 5 = Blinking<br />

blinking<br />

When the heating dem<strong>and</strong> is over, no new heating dem<strong>and</strong>s will go through the unit<br />

for 90 seconds. This function lengthens the boiler’s life-span.<br />

6.3.6 Changing the Set-point<br />

6.3.6.1 Changing the Set-point for Central Heating<br />

The set-point for heater water can be changed with<br />

the 4 <strong>and</strong> 5 buttons. When the heating water setpoint<br />

is changed, the following information will be<br />

displayed.<br />

Display Display Element<br />

Set-point, Central Heating Segment B <strong>and</strong> C<br />

Celsius-Symbol Segment D<br />

T a s t4 e<br />

L E D 4<br />

T a s t5 e<br />

blinking<br />

If the value is not changed within 5 Seconds, the display returns to the previous<br />

mode <strong>and</strong> the new set-point will be saved.<br />

6.3.6.2 Changing the Set-point for the Drinking-Water Heater<br />

The set-point for the drinking-water heater can be<br />

changed with the 6 <strong>and</strong> 7 buttons. When the drinking-water<br />

set-point is changed, the following information<br />

will be displayed.<br />

Display Display Element<br />

Set-point, Central Heating Segment B <strong>and</strong> C<br />

Celsius-Symbol Segment D<br />

T a s t 6e<br />

L E D 5<br />

T a s t 7e<br />

blinking<br />

If the value is not changed within 5 Seconds, the display returns to the previous<br />

mode <strong>and</strong> the new set-point will be saved.<br />

- 31 -<br />

Gebr. Bruns GmbH is not responsible for typographical errors or technical inaccuracies <strong>and</strong> reserves the right to make adjustments.<br />

Gebr. Bruns GmbH • Hauptstraße 200 • 26683 Saterl<strong>and</strong> •Tel.: + 49 (0) 44 92 / 92 46-0 • Fax: + 49 (0) 44 92 / 71 41<br />

www.bruns-heiztechnik.de • info@bruns-heiztechnik.de