Mounting / <strong>Installation</strong><br />

5.4 Start up<br />

After successfully ventilating <strong>and</strong> dejamming the unit, it will start in drinking water<br />

mode (if available); otherwise it will start in hot water mode. To start in hot water<br />

mode or in drinking water mode, the unit requires a certain level of heat. This can be<br />

done by opening the thermostats on the radiators. If an error occurs during the start<br />

up phase, it will be shown on the display (see error code list).<br />

5.4.1 Performance of the Unit Test Routine upon Start up<br />

After turning on the unit, a manual reset of every 12/24 hours, the control unit will<br />

perform a start up test routine. The 12/24 hour reset is dependent upon whether or<br />

not the heating dem<strong>and</strong>s require it.<br />

No heating dem<strong>and</strong>s: The control unit will reset every 12 hours<br />

Heating dem<strong>and</strong>s: The control unit will reset every 24 hours<br />

During the start up test routine, the three-way valve, if there is one, is switched to<br />

drinking water heating mode <strong>and</strong> directly after back to central heating mode, regardless<br />

of the previous position of the valve. This way, one complete pass is made by<br />

the valve, which keeps the valve from seizing. The circulation pump is also turned on<br />

during the test routine.<br />

5.5 (Pre) Setting the Boiler<br />

5.5.1 CO2 Boiler Settings<br />

The unit must be in chimney sweep<br />

mode (Ch. 6.3.8) when setting the CO2-<br />

levels.<br />

The amount of CO2 in the unit can be set<br />

with the adjusting screw on the gas<br />

valve.<br />

With liquid gas, the starting load must be<br />

change from 50% up to 60%.<br />

The CO2 – content must lie between the following levels, regardless of load:<br />

Gas Type CO2-Wert<br />

Natural Gas 8,5 – 9,0 %<br />

Liquid Gas 10 – 10,5 %<br />

- 26 -<br />

Gebr. Bruns GmbH is not responsible for typographical errors or technical inaccuracies <strong>and</strong> reserves the right to make adjustments.<br />

Gebr. Bruns GmbH • Hauptstraße 200 • 26683 Saterl<strong>and</strong> •Tel.: + 49 (0) 44 92 / 92 46-0 • Fax: + 49 (0) 44 92 / 71 41<br />

www.bruns-heiztechnik.de • info@bruns-heiztechnik.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!