Mounting / <strong>Installation</strong><br />
5.5.2 Gas Throughput Table / Connection Pressure<br />
Gas Type Load Area<br />
Gas Flow rate<br />
(l/min) Connection<br />
Pressure<br />
Min. Max.<br />
LL(L)-Gas 5,1 – 22,8 kW 11,6 50,1 20 mbar<br />
E(H)-Gas 5,1 – 22,8 kW 10,0 43,3 20 mbar<br />
Liquid Gas 5,1 – 22,8 kW 8,0 34,6 50 mbar<br />
Heating value: Natural Gas LL(L) = 8,83kWh/m³; Natural Gas E(H) = 10,22 kWh/m³; Liquid Gas = 12,78 kWh/m³<br />
The above gas type values may vary regionally. Please ask your energy provider for<br />
the heating values as necessary.<br />
5.5.3 Changing Gas Types<br />
Changing gas types does not require any adaptations to the unit. Simply adjust the<br />
CO2 Level (Ch. 5.5.1) to the respective gas type.<br />
- 27 -<br />
Gebr. Bruns GmbH is not responsible for typographical errors or technical inaccuracies <strong>and</strong> reserves the right to make adjustments.<br />
Gebr. Bruns GmbH • Hauptstraße 200 • 26683 Saterl<strong>and</strong> •Tel.: + 49 (0) 44 92 / 92 46-0 • Fax: + 49 (0) 44 92 / 71 41<br />
www.bruns-heiztechnik.de • info@bruns-heiztechnik.de