forming droplets, these drip into the fire or run out on the floor.<br />
This is common at the time of startup after installation, during<br />
periods of time when incoming water is very cold, or the heater<br />
may be undersized for the requirements.<br />
Droplets from the bottom of the flue may be due to corrosive<br />
combustion products or improper vent. Check <strong>with</strong> your dealer<br />
for more information.<br />
16<br />
CATHODIC PROTECTION - ANODE (FIG. 1)<br />
The anode rod <strong>with</strong>in the tank is designed to be slowly consumed<br />
cathodically, minimizing corrosion in the glass lined tank. A<br />
hydrogen sulfide (rotten egg) odor may result if water contains<br />
high sulfate and/or minerals. Chlorinating the water supply should<br />
minimize the problem. (See EXTENDED NON-USE PERIODS).<br />
NOTE: Anode must remain installed (except for inspection) to<br />
avoid shortening tank life. See LIMITED WARRANTY. Replace<br />
as necessary.<br />
WARNING: DO NOT BY-PASS ANY CONTROLS TO MAKE HEATER OPERATE.<br />
OPERATE ONLY AS WIRED FROM FACTORY.<br />
TROUBLE SHOOTING<br />
Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.<br />
Read the GENERAL SAFETY INFORMATION section first.<br />
PROBLEM LED STATUS CAUSE SOLUTION<br />
Check for power to heater.<br />
Off No power to system control. Check wiring harness for proper connections.<br />
Check for line voltage at harness connectors.<br />
Slow Blink<br />
Bright-Dim Normal operation Not applicable.<br />
1 Flash Setpoint error, internal failure detected. Replace gas control valve.<br />
Replace pressure switch.<br />
Replace pressure switch.<br />
2 Flashes Pressure switch failed to open. Replace blower assembly.<br />
Replace pressure switch.<br />
3 Flashes Pressure switch failed to close. Replace blower assembly.<br />
ECO activated. Replace ECO.<br />
4 Flashes Blower Assembly is energized. Replace gas control valve.<br />
Internal hardware failure. Replace gas control valve.<br />
Insure that burner stays lit.<br />
GAS Flame signal sensed out of sequence. Insure that igniter wires are not loose at gas valve.<br />
VALVE Replace gas control valve.<br />
Insure that burner stays lit.<br />
Blower Assembly is energized. Insure that igniter wires are not loose at gas valve.<br />
Replace gas control valve.<br />
<strong>Gas</strong> supply is off or too low to operate.<br />
Damaged or broken HSI element.<br />
Appliance not properly earth ground.<br />
Flame sense rod contaminated or not positioned<br />
correctly.<br />
6 Flashes System lockout. HSI element not positioned correctly.<br />
HSI element or flame sense rod wiring not<br />
connected properly.<br />
Less than 100Vac between flame rod and burner<br />
pan <strong>with</strong> 120Vac input to control.<br />
Cycle external power or remove request for heat<br />
for 2 seconds before reapplying.<br />
Water temperature is below 36°F. Wait until gas control generates a self-reset.<br />
Rapidly Loose connection between valve Make sure connections<br />
blinking and spud assembly. are properly seated.<br />
Internal component failure. Replace gas control valve.