26<br />

Commissioning without heat pump<br />

The indoor module can be run without heat pump, as<br />

only an electric boiler, to produce heat and hot water,<br />

for example before the heat pump is installed.<br />

Connect the pipe for docking in from the heat pump<br />

(XL8) with the pipe out from the heat pump (XL9).<br />

Enter menu 5.2.4 System settings and deactivate the heat<br />

pump.<br />

NOTE<br />

Select operating mode auto or <strong>manual</strong> when<br />

the indoor module is to run with the heat pump.<br />

Pump speed<br />

Both the circulation pumps in VVM 500 are frequency<br />

controlled and set themselves using control and external<br />

heating requirement. In the menu there are two operating<br />

modes for the circulation pumps, continuous and auto.<br />

If auto is selected the circulation pumps are controlled<br />

automatically by heating and hot water demands.<br />

��������<br />

Tillgängligt tryck<br />

����� (Pa)<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

LEK<br />

�������� ����������� ����<br />

��������� ��������� ����������� ����� ���<br />

25%<br />

0<br />

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8<br />

Luftflöde ���� ����� (l/s)<br />

Chapter 6 | Commissioning and adjusting<br />

100%<br />

��������<br />

Tillgängligt tryck<br />

����� (Pa)<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

�������� ����������� ����<br />

��������� ��������� ������ ����� ����<br />

25%<br />

0<br />

0 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8<br />

Luftflöde ���� ����� (l/s)<br />

100%<br />

Post-adjustment, venting<br />

Air is initially released from the hot water and venting<br />

may be necessary. If gurgling sounds can be heard from<br />

the climate system, the entire system will require additional<br />

venting. Vent the installation through the venting valves<br />

(QM20). When venting, VVM 500 must be off.<br />