PROGETTI<br />

SPECIAL HOUSE 9<br />

KIERAN TIMBERLAKE<br />

41<br />

ZOOM 1:<br />

INVOLUCRO EFFICIENTE IN CONTINUA TRASFORMAZIONE<br />

— EFFICIENT ENVELOP IN CONTINUOUS TRANSFORMATION<br />

Il progetto risulta tra i più efficienti in ambito residenziale<br />

rispetto alla certificazione prevista dal governo<br />

della California, avendo raggiunto un punteggio di 35<br />

HERS (Home Energy Rating), che, rapportato a una casa<br />

tradizionale in un contesto climatico affine, corrisponde<br />

al 65% in meno di consumi energetici. Queste elevate<br />

prestazioni sono state raggiunte grazie all’ottimizzazione<br />

dell’involucro, a un efficiente sistema impiantistico, che<br />

sfrutta prevalentemente energie rinnovabili e strategie di<br />

raffrescamento passive, insieme a un appropriato orientamento<br />

dell’edificio e a un bilanciato rapporto tra involucro<br />

opaco e trasparente.<br />

L’edificio è orientato su un asse est-ovest per limitare<br />

l’esposizione al sole durante l’estate. I guadagni solari, infatti,<br />

sono moderati da un grande sistema a traliccio, posto<br />

lungo tutta la facciata sud, che non solo fornisce ombra<br />

diretta, ma è pensato come un elemento che si trasforma<br />

nel tempo, grazie all’integrazione del verde. I vantaggi che<br />

ne derivano coprono tutto l’anno; se, infatti, in estate limita<br />

il surriscaldamento, in inverno permette il passaggio<br />

dei raggi solari, favorendo il riscaldamento dell’involucro<br />

e riducendo le dispersioni.<br />

Tra le altre strategie adottate si evidenziano: la ventilazione<br />

naturale, un bilanciato rapporto tra involucro<br />

traspirante e i sistemi schermanti, il recupero delle acque<br />

piovane in una cisterna per l’irrigazione e per usi igienicosanitari<br />

e, infine, l’uso di materiali locali.<br />

The project is amongst the most efficient in the residential<br />

context in relation to the certification required by the<br />

California government; it has achieved a 35 HERS (Home<br />

Energy Rating) score, which compared to a traditional<br />

house in a similar climatic context, corresponds to 65%<br />

less energy consumption.<br />

This high performance has been achieved thanks to the<br />

optimisation of the envelop, an efficient service system,<br />

which predominantly uses renewable energies and passive<br />

cooling strategies, combined with a suitable orientation<br />

of the buildings and a balanced ratio between opaque and<br />

transparent envelop.<br />

The building is east-west oriented to limit the exposure<br />

to the sun during the summer. The solar gains are indeed<br />

mitigated by a large wine trellis structure installed over the<br />

south facade which, not only provides direct shade, but it has<br />

also been conceived like an element which will transform<br />

through time, thanks to the integration of the green. The<br />

advantages can be appreciated throughout the year because<br />

this system will limit overheating during the summer, while<br />

in the winter will allow the entrance of solar radiation facilitating<br />

the heating of the envelop and reducing heat losses.<br />

Other strategies include: natural ventilation, a balanced<br />

relation between the transparent envelope and the<br />

screening systems, the collection of rainwater in a tank to<br />

be used for irrigation and sanitary purposes and ultimately<br />

the use of local materials.<br />

DATI ENERGETICI - ENERGY DATA<br />

energia primaria - primary energy<br />

energia finale - final energy<br />

fabbisogno di climatizzazione invernale - winter energy requirements<br />

24 kWh/m 2 a<br />

18 kWh/m 2 a<br />

25,2 kWh/m 2 a<br />

CONSUMI - CONSUMPTION<br />

esigenze di bilancio attuali - actual requirements<br />

energie rinnovabili alternative - alternative renewable energies<br />

domanda di elettricità, solare termica e pompa di funzionamento - electricity, solar thermal and heat pump demand<br />

9 kWh/m 2 a<br />

1 kWh/m 2 a<br />

7 kWh/m 2 a<br />

GUADAGNI - GAINS<br />

pan<strong>nell</strong>i fotovoltaici - photovoltaic panels 46 m 2 , inclination 30°<br />

impianto fotovoltaico esposto a nord-ovest - north-west facing photovoltaic system<br />

5 kWh/m 2 a<br />

impianto fotovoltaico esposto a sud-est - south-east facing photovoltaic system<br />

4 kWh/m 2 a<br />

impianto fotovoltaico esposto a sud - south facing photovoltaic system<br />

12 kWh/m 2 a