12.07.2015 Views

1. PDF dokument (13 MB) - dLib.si

1. PDF dokument (13 MB) - dLib.si

1. PDF dokument (13 MB) - dLib.si

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

MERITVE(Rs) zamika med krivuljama in tofunkcijo minimizirati. Kljuïne vrsticeizvedbe tega pristopa v programskemokolju Matlab so na sliki 12.Metodo iskanja smo preverili tudi napodatkih, pridobljenih z meritvami.Na slikah <strong>13</strong> in 14 vidimo zelo dobroujemanje med meritvami (rdeïakrivulja) in modelno funkcijo (modrakrivulja). V prvem primeru (sl. <strong>13</strong>) jestandardni odstopek med toïkamimodelne funkcije in izmerki 0,21mm oz. 0,15 mm v drugem primeru(slika 14).Slika 12. Izsek iz raÏunalniškega programa v jeziku Matlab,ki poišÏe zamik med krivuljama7 ZakljuÏekPreprosti laserski merilniki prisotnostilahko v nekaterih izvedbah služijotudi kot ekonomiïnaalternativamnogo dražjimoptiïnim mikrometrom.Takopri prvih kot pridrugih se moramozavedati, kakopomembnoje pravilno pozicioniranjemerjenca.Pokazalismo, kako drastiïno naraste napaka,ïe niso izpolnjeni v<strong>si</strong> pogoji pravilnemeritve. Nakazali smo možnost, darotiramo merjenec v svetlobnem snopuin s prilagajanjem parametrov modelnefunkcije izboljšamo meritev.Literatura[1] Doebelin, Ernest O. 2004. Measurementsystems applicationand de<strong>si</strong>gn; 5th ed., McGraw-Hill series in mechanical engineering.[2] http://www.keyence.co.uk/.[3] http://www.mathworks.com/.Accuracy of an attributivelaser through-beam sensorSlika <strong>13</strong>. Odvisnost, dobljena z merjenjem, in modelna funkcija potem, ko smopoiskali zaÏetni zamik. Merjenec je imel stranici a = 5 in b = 9 mmAbstract: Universal laser throughbeamsensors are important piecesof equipment in productionautomation. Some of the configurationscan also be used for themeasurement of dimen<strong>si</strong>ons. Inthis research we were interested inhow precise these measurementsare and how can the error due tothe misalignment of the measuredpiece be avoided. We haveshown how the dark-field widthcan be <strong>si</strong>mulated and how theparameters of the model functioncan be fitted to measurementresults performed with a rotatingmeasured object.Keywards: through-beam lasersensor, alignment error, measurement<strong>si</strong>mulation,Slika 14. Odvisnost, dobljena z merjenjem, in modelna funkcija potem, kosmo poiskali zaÏetni zamik. Merjenec je imel stranici a = 8 in b = 9 mmZahvalaZahvaljujemo se podjetju Gazela,d. o. o., ki je odstopilo opremo,uporabljeno v tem prispevku.256 Ventil 14 /2008/ 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!