Target module »DVI-CPU-MC2«<br />
Click the icon to get information about the channel assignment and the names of the<br />
grouped modules.<br />
NOTE: You can adjust multichannel configurations no matter if they are created<br />
automatically or manually. The chapter Expanding through port grouping of the web<br />
application manual provides more information about how to adjust multichannel<br />
configurations.<br />
Status displays<br />
The LED on the back panel of the user module inform you about the status of the<br />
external power pack:<br />
LED Status Meaning<br />
Power on The external power pack is connected and the required voltage (12 Volt)<br />
is available.<br />
The flashing Transmission LEDs highlight the following operating statuses of the<br />
particular connection:<br />
13 · G&D <strong>DVICenter</strong><br />
off The external power pack is not (properly) connected.<br />
LED Status Meaning<br />
Yellow Off No user module accesses the target module.<br />
On A user module accesses the target module.<br />
Blinking The incoming video signal was not detected.<br />
Flashing No voltage at PS/2 interface or USB bus.<br />
Green Off The target module is turned off.<br />
Blinking The power pack is connected and supplies the required power.<br />
The connection to the central module could not be established.<br />
Flashing The connection to the central module is established.<br />
No user module is accessing or the computer is turned off.<br />
On A user module accesses the target module.<br />
A computer is connected and turned on.<br />
Flickering Keyboard and mouse inputs are transmitted by the accessing user module.<br />
The flickering is defined by the user’s inputs.