Betriebs- und Installationsanweisung Operating and Installation ...
Betriebs- und Installationsanweisung Operating and Installation ...
Betriebs- und Installationsanweisung Operating and Installation ...
Erfolgreiche ePaper selbst erstellen
Machen Sie aus Ihren PDF Publikationen ein blätterbares Flipbook mit unserer einzigartigen Google optimierten e-Paper Software.
<strong>Installation</strong> instructions<br />
Filling the steam generator<br />
The appliance must be completely disconnected from the<br />
electricity mains!<br />
Only use drinking water to fill the steam generator!<br />
=<br />
Loosen clip on the hose for checking the filling level 1 <strong>and</strong> remove<br />
the stopper. Guide the hose section out of the appliance.<br />
Connect a water hose to the filling tap.<br />
Open the filling tap <strong>and</strong> fill with water until the water overflows.<br />
Open the safety valve by turning the nut s anticlockwise. You can tell<br />
when the safety valve is open when the nut s makes a clicking noise<br />
when being turned. Opening this valve ventilates the pressure vessel<br />
<strong>and</strong> prevents overfilling. When no more water flows out of the hose<br />
pipe, close the safety valve by turning the nut s clockwise until it sits<br />
firmly. Then close the filling tap <strong>and</strong> remove the water hose.<br />
Mount the stopper back onto the hose for checking the filling level <strong>and</strong><br />
secure with hose clip.<br />
At the filling tap: unscrew the hose cover <strong>and</strong> attach the lid.<br />
=<br />
When the installation work has been completed, all panels must<br />
be remounted!<br />
Emptying the steam generator<br />
The steam generator only needs to be emptied<br />
- for certain types of service jobs<br />
- when the pan is being stored or if temperatures of less than 0 °C<br />
are to be expected for any reason.<br />
To empty the pressure vessel, open the filling tap as you do when filling<br />
it. Make sure that it is completely drained.<br />
For the capacity, please refer to “Technical data” on page 37.<br />
FGS/UGS 07 25 17 Bl.35 35