Installation Manual - CertainTeed
Installation Manual - CertainTeed
Installation Manual - CertainTeed
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>CertainTeed</strong> WeatherBoards Fiber Cement Siding <strong>Installation</strong> <strong>Manual</strong><br />
XXThe combined thickness of the non-structural materials<br />
(insulated sheathing, non-structural lathe/furring strips,<br />
etc.) between framing members and exterior cladding<br />
must not exceed 1". Requirements for the thickness<br />
of lathe/furring strip may vary, so check with your<br />
local code official or governing body for the building<br />
requirements in your area.<br />
XXFor best results, apply lathe/furring strips directly over<br />
weather-resistant-barrier-clad structural sheathing that<br />
is attached to framing members.<br />
XXAdhere to all flashing, cutting, and sealing requirements<br />
outlined in the most current version of this manual.<br />
NOTE: Horizontal installation of furring strips may<br />
be required when installing fiber cement shake<br />
products. Using solid furring strips is discouraged in<br />
this type of installation. The ultimate responsibility<br />
for water management and diversion is the<br />
responsibility of the rainscreen system designer.<br />
Insulated Concrete Forms<br />
Typically, an Insulated Concrete Form (ICF) wall system<br />
relies on a plastic strip to provide the attachment<br />
point for exterior cladding. Since ICF wall systems<br />
are manufactured proprietary designs, only the<br />
ICF manufacturer can determine if the system can<br />
accommodate the applied loads created by attaching<br />
fiber cement siding.<br />
We can provide information on the weight of the siding<br />
material and the types of fasteners used with fiber cement<br />
siding, but it is up to you to contact the ICF manufacturer<br />
to determine how best (if possible) to attach the fiber<br />
cement siding to the specific ICF system.<br />
Recommended Fasteners to Install Fiber Cement Siding over Furring 1<br />
Product Furring Fastener Fastening Method<br />
Lap Siding Wood 1-1/4", 11 ga. roofing nail Blind nailed into 1 x 4 furring<br />
Vertical Siding Wood 2" 6d siding nail<br />
Lap Siding Steel<br />
Vertical Siding Steel<br />
6" along the edges; 12"<br />
in the field into the furring<br />
Pins Must penetrate furring 1/4"<br />
Screws Must penetrate furring 3 full turns<br />
Pins Must penetrate furring 1/4"<br />
Screws Must penetrate furring 3 full turns<br />
1 Wall construction must allow full penetration of the fastener through the furring.<br />
25