<strong>CertainTeed</strong> WeatherBoards Fiber Cement Siding <strong>Installation</strong> <strong>Manual</strong><br />

XXThe combined thickness of the non-structural materials<br />

(insulated sheathing, non-structural lathe/furring strips,<br />

etc.) between framing members and exterior cladding<br />

must not exceed 1". Requirements for the thickness<br />

of lathe/furring strip may vary, so check with your<br />

local code official or governing body for the building<br />

requirements in your area.<br />

XXFor best results, apply lathe/furring strips directly over<br />

weather-resistant-barrier-clad structural sheathing that<br />

is attached to framing members.<br />

XXAdhere to all flashing, cutting, and sealing requirements<br />

outlined in the most current version of this manual.<br />

NOTE: Horizontal installation of furring strips may<br />

be required when installing fiber cement shake<br />

products. Using solid furring strips is discouraged in<br />

this type of installation. The ultimate responsibility<br />

for water management and diversion is the<br />

responsibility of the rainscreen system designer.<br />

Insulated Concrete Forms<br />

Typically, an Insulated Concrete Form (ICF) wall system<br />

relies on a plastic strip to provide the attachment<br />

point for exterior cladding. Since ICF wall systems<br />

are manufactured proprietary designs, only the<br />

ICF manufacturer can determine if the system can<br />

accommodate the applied loads created by attaching<br />

fiber cement siding.<br />

We can provide information on the weight of the siding<br />

material and the types of fasteners used with fiber cement<br />

siding, but it is up to you to contact the ICF manufacturer<br />

to determine how best (if possible) to attach the fiber<br />

cement siding to the specific ICF system.<br />

Recommended Fasteners to Install Fiber Cement Siding over Furring 1<br />

Product Furring Fastener Fastening Method<br />

Lap Siding Wood 1-1/4", 11 ga. roofing nail Blind nailed into 1 x 4 furring<br />

Vertical Siding Wood 2" 6d siding nail<br />

Lap Siding Steel<br />

Vertical Siding Steel<br />

6" along the edges; 12"<br />

in the field into the furring<br />

Pins Must penetrate furring 1/4"<br />

Screws Must penetrate furring 3 full turns<br />

Pins Must penetrate furring 1/4"<br />

Screws Must penetrate furring 3 full turns<br />

1 Wall construction must allow full penetration of the fastener through the furring.<br />