4-12 Configuring the <strong>DeviceNet</strong> Network<br />

Publication <strong>1747</strong>-<strong>6.5.5</strong> - August 2000<br />

2. Make sure that the Polled box is checked and that the Rx Size and<br />

Tx Size are each 1 byte.<br />

3. Click on OK to close the Edit I/O Parameters window for the<br />

RediSTATION.<br />

4. Click on OK again. You will be prompted to download the changes<br />

to the <strong>1747</strong>-SDN module.<br />

5. Click on Yes to download the new configuration.<br />

AutoMapping the Devices into the Scanlist<br />

Follow the procedure below to automatically map the photoeye and<br />

RediSTATION to the <strong>SL</strong>C <strong>500</strong> processor.<br />

TIP<br />

If you want to know how to map the devices<br />

manually, click on the Help button at the bottom of<br />

the screen and select “Map device input data<br />

manually”.<br />

1. Double-click on the <strong>1747</strong>-SDN module icon and select the Input<br />

tab.