30 Installation (for qualified installers only)<br />
Rear Vent Configuration with Vertical Termination<br />
• The termination must fall<br />
within the shaded area<br />
shown in the chart. Use the<br />
indicated restrictor and<br />
diffuser positions.<br />
• Up to four elbows (45° or<br />
90°) may be used.<br />
• Only one horizontal elbow<br />
may be used (see<br />
illustration at the bottom of<br />
the page).<br />
• Use 8" diameter vent.<br />
This is considered a horizontal<br />
elbow (it does not matter<br />
whether it turns right or left).<br />
It may be a 90° or 45° elbow.<br />
40' (max)<br />
Restrictor Position # 3<br />
Diffuser Position # 1 (stock)<br />
NOTE:<br />
Two 45° elbows<br />
may be used.<br />
NOTE:<br />
One 45° or 90° elbow may<br />
be used between horizontal<br />
sections. Horizontal length<br />
is caculated by adding each<br />
horizontal run together.<br />
NOTE:<br />
Horizontal sections require a<br />
1/4" rise every 12" of travel.<br />
H2<br />
H1<br />
<br />
<br />
NOTE:<br />
<br />
<br />
Restrictor positions are<br />
based upon lab tests.<br />
<br />
<br />
The ideal restrictor<br />
position may vary<br />
<br />
<br />
slightly, especially when<br />
the termination is near a<br />
demarkation line.<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Restrictor Position # 2<br />
Diffuser Position # 1 (stock)<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Restrictor Position # 1 (stock)<br />
<br />
<br />
Diffuser Position # 1 (stock)<br />
<br />
<br />
<br />
<br />
<br />
6' (min) 6' (min)<br />
5 feet<br />
5 feet<br />
© Travis Industries 4080207 100-01185_000<br />
35 feet<br />
30 feet<br />
25 feet<br />
20 feet<br />
15 feet<br />
10 feet<br />
0 feet<br />
0 feet<br />
0 feet<br />
5 feet<br />
5 feet<br />
10 feet<br />
10 feet<br />
Horizontal length is calculated by adding<br />
both lengths of horizontal run<br />
(Horizontal Length = H1 + H2).<br />
This is considered a<br />
vertical elbow<br />
14' (max)<br />
14' (max)<br />
40' (max)<br />
35 feet<br />
30 feet<br />
25 feet<br />
20 feet<br />
15 feet<br />
10 feet<br />
0 feet