38 Installation (for qualified installers only)<br />

Mantel Requirements<br />

• The illustration below details mantel clearances and maximum mantel depth.<br />

• Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel<br />

and must meet the mantel requirements.<br />

Mantel<br />

Height<br />

Above<br />

Face (a)<br />

9”<br />

8”<br />

7”<br />

6”<br />

5”<br />

4”<br />

3”<br />

2”<br />

1”<br />

0”<br />

Maximum Mantel Depth (b)<br />

0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”<br />

If you have a tapered mantel, measure the<br />

mantel height at the point where it<br />

protrudes 3/4” in front of the face.<br />

a<br />

See “Face Dimensions”<br />

b<br />

Mantel<br />

(combustible or non-combustible)<br />

Combustible mantel columns (legs) that<br />

protrude more than 3/4” from the glass<br />

frame must meet the sidewall clearance (1”<br />

from the face). If they protrude 3/4” or less,<br />

they do not have a minimum clearance.<br />

Non-combustible mantel columns do not<br />

have a minimum clearance.<br />

© Travis Industries 4080207 100-01185_000