38 Installation (for qualified installers only)<br />
Mantel Requirements<br />
• The illustration below details mantel clearances and maximum mantel depth.<br />
• Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel<br />
and must meet the mantel requirements.<br />
Mantel<br />
Height<br />
Above<br />
Face (a)<br />
9”<br />
8”<br />
7”<br />
6”<br />
5”<br />
4”<br />
3”<br />
2”<br />
1”<br />
0”<br />
Maximum Mantel Depth (b)<br />
0” 1” 2” 3” 4” 5” 6” 7” 8” 9” 10” 11” 12”<br />
If you have a tapered mantel, measure the<br />
mantel height at the point where it<br />
protrudes 3/4” in front of the face.<br />
a<br />
See “Face Dimensions”<br />
b<br />
Mantel<br />
(combustible or non-combustible)<br />
Combustible mantel columns (legs) that<br />
protrude more than 3/4” from the glass<br />
frame must meet the sidewall clearance (1”<br />
from the face). If they protrude 3/4” or less,<br />
they do not have a minimum clearance.<br />
Non-combustible mantel columns do not<br />
have a minimum clearance.<br />