Clay Tile<br />

1. COMPANY NAME LUDOWICI ROOF LUDOWICI ROOF LUDOWICI ROOF<br />

TILE, INC. TILE, INC. TILE, INC.<br />

2 PRODUCT NAME 18" SBM CLOSED SHINGLE FLAT SLAB<br />

SHINGLE<br />

3. TILE TYPE<br />

"S" (Spanish) Mission Barrel, One Piece<br />

Straight Barrel Mission, Two Piece X<br />

Tapered Mission, Two Piece<br />

Flat, One Piece X<br />

Flat, Interlocking, One Piece X<br />

Flat Pan and Cover, Two Piece<br />

4A. TILE DESCRIPTION<br />

Texture (specify or NA) FINE MACHINE SCORED SMOOTH/SANDED SMOOTH/SANDED<br />

4B. FINISHES NATURAL / CERAMIC GLAZE NATURAL / CERAMIC GLAZE NATURAL / CERAMIC GLAZE<br />

Number of Colors Available 1 / 47 1 / 47 1 / 47<br />

Color Availability (regional/national) NATIONAL / NATIONAL NATIONAL / NATIONAL NATIONAL / NATIONAL<br />

Custom Colors/Blends Available (yes/no) NO / YES NO / YES NO / YES<br />

Custom Shapes Available (yes/no) YES / YES YES / YES YES / YES<br />

5. ACCESSORY TILES AVAILABLE [e.g., ridge, hip, starter] (yes/no) YES YES YES<br />

6. DIMENSIONS AND COVERAGE<br />

Tile Dimensions (inches x inches) 18-3/8 X 8 11 X 8-3/4 12 X 6<br />

Exposed Size (inches x inches) 15-3/8 X 5-3/4 8 X 8 5 X 6<br />

Pieces Per Roof Square 163 225 480<br />

Weight Per Roof Square (pounds) 1165 1130 1300/1780<br />

7. SLOPE/UNDERLAYMENT RECOMMENDATIONS<br />

A. Minimum Slope Recommended For <strong>No</strong>rmal Application (inches per foot) 5:12 3:12 5:12<br />

B. Underlayment Recommended In <strong>No</strong>rmal Application 40 LB. FELT 40 LB. FELT 40 LB. FELT<br />

C. Minimum Slope Recommended For Special Applications (inches per foot<br />

or NA)<br />

3:12 3:12<br />

D. Underlayment Recommended in Special Application WINTERGUARD OR WINTERGUARD OR<br />

8. DECKS AND FASTENING RECOMMENDATIONS (Fastening system in<br />

normal application or NA)<br />

BUR EQUIVALENT BUR EQUIVALENT<br />

Metal STAINLESS STEEL SHEET STAINLESS STEEL SHEET STAINLESS STEEL SHEET<br />

METAL SCREWS METAL SCREWS METAL SCREWS<br />

Plywood 11 GAUGE RING SHANK 11 GAUGE RING SHANK 11 GAUGE RING SHANK<br />

COPPER NAILS COPPER NAILS COPPER NAILS<br />

Wood Plank 11 GA SMOOTH SHANK 11 GA SMOOTH SHANK 11 GA SMOOTH SHANK<br />

COPPER NAILS COPPER NAILS COPPER NAILS<br />

Oriented-Strand Board NA NA NA<br />

Waferboard NA NA NA<br />

Gypsum / Nailable Concrete SPIRAL THREAD STAINLESS SPIRAL THREAD STAINLESS SPIRAL THREAD STAINLESS<br />

STEEL/SILICON BRONZE NAIL STEEL/SILICON BRONZE NAIL STEEL/SILICON BRONZE NAIL<br />

O<strong>the</strong>r (specify) NA NA NA<br />

9. YEAR PRODUCT FIRST SOLD 1996 1900 1900<br />

10. NUMBER OF SQUARES INSTALLED >10,000 >250,000 >5,000<br />

11. DISTRIBUTION<br />

Distributors (number handling product or no) >50 >50 >50<br />

Direct (number of regional service locations or no) 1 1 1<br />

12. TECHNICAL INFORMATION COMPLIES WITH ASTM C1167-96<br />

STANDARD SPECIFICATION FOR CLAY ROOF TILE<br />

(check grade and type or enter none)<br />

GRADE 1 Providing resistance to severe frost action X X X<br />

GRADE 2 Providing resistance to moderate frost action<br />

GRADE 3 Providing negligible resistance to any frost action<br />

TYPE I High-profile: rise-to-width ratio greater than 1:5 X<br />

TYPE II Low-profile: rise-to-width ratio equal to or less than 1:5<br />

TYPE III All o<strong>the</strong>r tiles, including flat X X<br />

13. ACCEPTED BY THE FOLLOWING CODES ICBO (4872), UBC, ICBO (4872), UBC, ICBO (4872), UBC,<br />

METRO-DADE COUNTY, METRO-DADE COUNTY, METRO-DADE COUNTY,<br />

FL. FL. FL.<br />

14. FOR SALES INFORMATION, CONTACT:<br />

800/945-8453 800/945-8453 800/945-8453<br />

FOR TECHNICAL INFORMATION, CONTACT:<br />

800/945-8453 800/945-8453 800/945-8453<br />

15. SEE APPENDIX IF CHECKED X X X<br />

NA=not applicable<br />