Asphalt Shingles Part 1: General Information<br />

1. COMPANY NAME MALARKEY MALARKEY MALARKEY<br />

ROOFING ROOFING ROOFING<br />

COMPANY COMPANY COMPANY<br />

2. PRODUCT NAME #240 HURRICANE #271 #272<br />

SBS MODIFIED HIGHLANDER 25 LEGACY 35<br />

ALGAE RESISTANT SBS MODIFIED<br />

3. PRODUCT DESCRIPTION<br />

Felt Material (organic/fiberglass) POLYGLASS FIBERGLASS POLYGLASS<br />

Construction (laminated/nonlaminated) NONLAMINATED LAMINATED LAMINATED<br />

Granule Composition CERAMIC & COPPER CERAMIC CERAMIC<br />

Number of Colors Available (/ marks number <strong>by</strong> region) 7 6 8<br />

Color Availability (regional/national) REGIONAL NATIONAL NATIONAL<br />

4. SHINGLE TYPE<br />

Self-Sealing 3-Tab Strip X<br />

Self-Sealing 4-Tab Strip<br />

Self-Sealing Random-Tab Strip<br />

Self-Sealing <strong>No</strong> Cutout X X<br />

Individual Interlocking<br />

5. AVAILABILITY RESTRICTED REGIONALLY (yes/no) NO NO NO<br />

6A. DIMENSIONS AND COVERAGE: SIZE 1<br />

Shingle Dimensions (inches x inches) 13 1/4 X 39 3/8 13 1/4 X 39 13 1/4 X 40<br />

Exposure (inches) 5 5/8 5 5/8 5 5/8<br />

Headlap (inches) 7 5/8 7 5/8 7 5/8<br />

Shingles Per Roof Square 66 64 64<br />

Bundles Per Square 3 4 4<br />

Weight Per Roof Square (pounds) 235 245 275<br />

6B. DIMENSIONS AND COVERAGE: SIZE 2<br />

Shingle Dimensions (inches x inches)<br />

Exposure (inches)<br />

Headlap (inches)<br />

Shingles Per Roof Square<br />

Bundles Per Square<br />

Weight Per Roof Square (pounds)<br />

7. HIP/RIDGE SHINGLE AVAILABLE (nationally, regionally, no) NATIONALLY NATIONALLY NATIONALLY<br />

8. SLOPE/UNDERLAYMENT RECOMMENDATIONS<br />

Minimum Slope Recommended For <strong>No</strong>rmal Application (inches per foot) 4:12 4:12 4:12<br />

Underlayment Recommended in <strong>No</strong>rmal Application 15- OR 30-LB. FELT 15- OR 30-LB. FELT 15- OR 30-LB. FELT<br />

#501 UDL #501 UDL #501 UDL<br />

Minimum Slope Recommended For Special Application (inches per foot) 2:12 2:12 2:12<br />

Underlayment Recommended in Special Application 2 15-LB. FELTS 2 15-LB. FELTS 2 15-LB. FELTS<br />

OR 2 #501 UDL OR 2 #501 UDL OR 2 #501 UDL<br />

9. RECOMMENDED DECK MATERIAL<br />

Plywood/Wood X X X<br />

Oriented-Strand Board<br />

Waferboard<br />

O<strong>the</strong>r (specify)<br />

10. YEAR PRODUCT FIRST SOLD 1993 1997 1997<br />

11. NUMBER OF SQUARES INSTALLED<br />

12. MANUFACTURERS PLANT LOCATIONS PORTLAND, OR PORTLAND, OR PORTLAND, OR<br />

(CITY, STATE)<br />

13 DISTRIBUTION<br />

Distributors (number handling product or no) 200+ 200+ 200+<br />

Direct (number of regional service locations or no)<br />

14A. FOR SALES INFORMATION, CONTACT: G. MALARKEY G. MALARKEY G. MALARKEY<br />

800/545-1191 800/545-1191 800/545-1191<br />

14B FOR TECHNICAL INFORMATION, CONTACT: J. DECHANDT J. DECHANDT J. DECHANDT<br />

M. MALARKEY M. MALARKEY M. MALARKEY<br />

15. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />