28.03.2013 Views

2000 by the National Roofing Contractors Association. No

2000 by the National Roofing Contractors Association. No

2000 by the National Roofing Contractors Association. No

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Clay Tile<br />

1. COMPANY NAME TBF TILE TUILERIE DE PONTIGNY TUILERIE DE PONTIGNY<br />

ALEONARD ALEONARD<br />

2 PRODUCT NAME LA GAULOISE MONUMENT GLAZED<br />

HISTORIQUE<br />

3. TILE TYPE<br />

"S" (Spanish) Mission Barrel, One Piece<br />

Straight Barrel Mission, Two Piece<br />

Tapered Mission, Two Piece<br />

Flat, One Piece X X<br />

Flat, Interlocking, One Piece X<br />

Flat Pan and Cover, Two Piece<br />

4A. TILE DESCRIPTION<br />

Texture (specify or NA) SMOOTH N/A N/A<br />

4B. FINISHES NATURAL / CERAMIC GLAZE NATURAL / CERAMIC GLAZE NATURAL / CERAMIC GLAZE<br />

Number of Colors Available 2 / 2 3 / -- 14 / --<br />

Color Availability (regional/national) NATIONAL / NATIONAL NATIONAL / -- NATIONAL / --<br />

Custom Colors/Blends Available (yes/no) NO / NO YES / -- YES / --<br />

Custom Shapes Available (yes/no) NO / NO YES / -- YES / --<br />

5. ACCESSORY TILES AVAILABLE [e.g., ridge, hip, starter] (yes/no) YES YES YES<br />

6. DIMENSIONS AND COVERAGE<br />

Tile Dimensions (inches x inches) 16-1.2 X 19 13 X 6-3/4 11-3/4 X 6-3/4<br />

Exposed Size (inches x inches) 12-1/2 X 8-1/2 5-1/2 X 6-3/4 4-3/4 X 6-/34<br />

Pieces Per Roof Square 140 390 430<br />

Weight Per Roof Square (pounds) 1050 1500 1570<br />

7. SLOPE/UNDERLAYMENT RECOMMENDATIONS<br />

A. Minimum Slope Recommended For <strong>No</strong>rmal Application (inches per foot) 4:12 10:12 10:12<br />

B. Underlayment Recommended In <strong>No</strong>rmal Application 40 LB. FELT 40 LB. FELT 40 LB. FELT<br />

C. Minimum Slope Recommended For Special Applications (inches per foot<br />

or NA)<br />

D. Underlayment Recommended in Special Application<br />

8. DECKS AND FASTENING RECOMMENDATIONS (Fastening system in<br />

normal application or NA)<br />

Metal STAINLESS STEEL BATTEN SEAM BATTEN SEAM<br />

Plywood RING SHANK<br />

Wood Plank<br />

Oriented-Strand Board<br />

Waferboard<br />

Gypsum / Nailable Concrete<br />

O<strong>the</strong>r (specify)<br />

9. YEAR PRODUCT FIRST SOLD 1996 1800 1800<br />

10. NUMBER OF SQUARES INSTALLED N/A N/A N/A<br />

11. DISTRIBUTION<br />

Distributors (number handling product or no) -- -- --<br />

Direct (number of regional service locations or no) X X X<br />

12. TECHNICAL INFORMATION COMPLIES WITH ASTM C1167-96<br />

STANDARD SPECIFICATION FOR CLAY ROOF TILE<br />

(check grade and type or enter none)<br />

GRADE 1 Providing resistance to severe frost action X X X<br />

GRADE 2 Providing resistance to moderate frost action<br />

GRADE 3 Providing negligible resistance to any frost action<br />

TYPE I High-profile: rise-to-width ratio greater than 1:5<br />

TYPE II Low-profile: rise-to-width ratio equal to or less than 1:5<br />

TYPE III All o<strong>the</strong>r tiles, including flat X X X<br />

13. ACCEPTED BY THE FOLLOWING CODES<br />

14. FOR SALES INFORMATION, CONTACT: S. MATTHEWS S. MATTHEWS S. MATTHEWS<br />

905/627-4035 905/627-4035 905/627-4035<br />

FOR TECHNICAL INFORMATION, CONTACT: S. MATTHEWS S. MATTHEWS S. MATTHEWS<br />

905/527-4035 905/527-4035 905/527-4035<br />

15. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />

144

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!