Metal Panels<br />

1. COMPANY NAME ARS INDUSTRIES, INC. ATAS INTERNATIONAL INC.<br />

2. PRODUCT NAME SSC PC SNAP-ON SEAM/BATTEN<br />

3 CONFIGURATION<br />

3.1 STYLE<br />

A. Simulated Shingle (specific type if applicable)<br />

B. Simulated Shake (specific type if applicable)<br />

C. Simulated Slate (specific type if applicable)<br />

D. Simulated Tile (specific type if applicable)<br />

E. O<strong>the</strong>r (specify type) SNAP-ON BATTEN STANDING SEAM SNAP-ON SEAM/SNAP-ON BATTEN STANDING SEAM<br />

3.2 COMPONENT TYPE AND SIZE<br />

A. Panel [width (in.), maximum length (ft.)] 12, 16, 18, 20, 24 X 50 12-1/2, 15-1/4 X 65<br />

B. Individual (dimensions: inches x inches)<br />

3.3 MATERIALS, THICKNESSES, AND FINISHES<br />

GALVANIZED STEEL (ga.): Thicknesses 22, 26 24<br />

Finishes KYNAR 500, SILICON POLYESTER, MILL KYNAR 500<br />

STAINLESS STEEL (ga.) Thicknesses 22, 26<br />

Finishes KYNAR 500, SILICON POLYESTER, MILL<br />

GALVALUME (ga.) Thicknesses 22, 26<br />

Finishes KYNAR 500, SILICON POLYESTER, MILL<br />

ALUMINIZED STEEL (ga.) Thicknesses 22, 26<br />

Finishes KYNAR 500, SILICON POLYESTER, MILL<br />

ALUMINUM (in.) Thicknesses 0.19, 0.32, 0.40 0.032, 0.040<br />

Finishes KYNAR 500, SILICON POLYESTER, MILL KYNAR 500<br />

COPPER (oz.) Thicknesses 16, 20 16<br />

Finishes MILL --<br />

TERNE METAL (ga.) Thicknesses 22, 26<br />

Finishes MILL<br />

ZINC (ga.) Thicknesses --<br />

Finishes --<br />

4. SYSTEMS RECOMMENDATIONS<br />

Min. Slope Recommended In <strong>No</strong>rmal Application (in. per ft.) 3:12 3:12<br />

Min. Slope Recommended In Special Application (in. per ft.) -- 3:12<br />

DECK TYPES'<br />

Solid Deck, Wood X X<br />

Spaced Sheathing, Wood X<br />

Decking <strong>No</strong>t Required X<br />

Underlayment Recommended (type or NA) 30 LB. FELT OR EQUIVALENT 30 LB. FELT<br />

5. PANEL CONFIGURATION (For components in item 3.2A<br />

above; for individual components, see item 6.)<br />

5.1 INTERLOCKING METHOD, HEIGHT (inches), AND SEAM SEALANT HEIGHT (inches) / SEAM SEALANT (F = Factory HEIGHT (inches) / SEAM SEALANT (F = Factory<br />

Applied; E = Field applied; N = <strong>No</strong>ne) Applied; E = Field applied; N = <strong>No</strong>ne)<br />

Overlapped<br />

Interlocked<br />

Slip Locked 1 / F, E<br />

Snap Toge<strong>the</strong>r 1-1/4 / N<br />

5.2 FASTENING METHOD<br />

Through Fastened (exposed or concealed, specify)<br />

Clip (exposed or concealed, specify) CONCEALED CONCEALED<br />

6. INDIVIDUAL COMPONENT CONFIGURATION (For components<br />

in item 3.2B above; for panels, see item 5.)<br />

6.1 DIMENSIONS<br />

Weight Per Roof Square (pounds)<br />

Exposure (inches)<br />

Coverage (approx. no. of pieces per square at listed exposure)<br />

6.2 INSTALLATION PROCESSING<br />

Through-Fastened (exposed or concealed, specify)<br />

Kind(s) Of Fastener Required (nails, staples, screws, NA)<br />

Number Of Fasteners Per Piece (number or NA)<br />

Seam Snap-In Or Interlock (specify or NA)<br />

Adhesive/Sealant Required (yes/no)<br />

Support Battens Required (yes/no)<br />

7. MANUFACTURER/PRODUCT DATA<br />

Year Product First Sold 1980 1979<br />

Number of Squares Installed 1 MILLION + > 100,000<br />

Method Of Distribution (distributors, direct) DISTRIBUTORS, DIRECT DISTRIBUTORS<br />

Number Of Rgional Service Locations 1 2<br />

Licensed Applicator Agreement (yes/no) YES NO<br />

For Sales Information, Contact C. LEVERETT 205/836-6777 J. BUSH 610/395-8446<br />

For Technical Information, Contact M. WEED 205/836-6777 J. BUSH 610/395-8446<br />

8. ASTM E331 WATER PENETRATION TEST RESULTS<br />

(results or none)<br />

-- NONE<br />

9. ASTM E1646 WATER PENETRATION TEST RESULTS<br />

(results or none)<br />

10. ASTM E283 AIR INFILTRATION TEST RESULTS<br />

(results or none)<br />

-- NONE<br />

11. ASTM E1680 AIR INFILTRATION TEST RESULTS<br />

(results or none)<br />

10. UL FIRE RATINGS FOR ANY SPECIFICATION (per UL 790) CLASS A CLASS A<br />

11. FM/UL WIND UPLIFT RATING FOR ANY SPECIFICATION -- UL-90<br />

12. SEE APPENDIX IF CHECKED X<br />

NA=not applicable<br />