Metal Panels<br />

1. COMPANY NAME PETERSEN ALUMINUM CORP. PETERSEN ALUMINUM CORP.<br />

2. PRODUCT NAME FLUSH PANEL REVEAL PANEL<br />

3 CONFIGURATION<br />

3.1 STYLE<br />

A. Simulated Shingle (specific type if applicable)<br />

B. Simulated Shake (specific type if applicable)<br />

C. Simulated Slate (specific type if applicable)<br />

D. Simulated Tile (specific type if applicable)<br />

E. O<strong>the</strong>r (specify type) STANDING SEAM STANDING SEAM<br />

3.2 COMPONENT TYPE AND SIZE<br />

A. Panel [width (in.), maximum length (ft.)] 7-18 X 40 7-18 X 40<br />

B. Individual (dimensions: inches x inches)<br />

3.3 MATERIALS, THICKNESSES, AND FINISHES<br />

GALVANIZED STEEL (ga.): Thicknesses 22, 24 22, 24<br />

Finishes KYNAR 500 KYNAR 500<br />

STAINLESS STEEL (ga.) Thicknesses<br />

Finishes<br />

GALVALUME (ga.) Thicknesses<br />

Finishes<br />

ALUMINIZED STEEL (ga.) Thicknesses<br />

Finishes<br />

ALUMINUM (in.) Thicknesses 0.032 0.032<br />

Finishes KYNAR 500 KYNAR 500<br />

COPPER (oz.) Thicknesses<br />

Finishes<br />

TERNE METAL (ga.) Thicknesses<br />

Finishes<br />

ZINC (ga.) Thicknesses<br />

Finishes<br />

4. SYSTEMS RECOMMENDATIONS<br />

Min. Slope Recommended In <strong>No</strong>rmal Application (in. per ft.) -- --<br />

Min. Slope Recommended In Special Application (in. per ft.) -- --<br />

DECK TYPES'<br />

Solid Deck, Wood X X<br />

Spaced Sheathing, Wood X X<br />

Decking <strong>No</strong>t Required<br />

Underlayment Recommended (type or NA) 30 LB. FELT 30 LB. FELT<br />

5. PANEL CONFIGURATION (For components in item 3.2A<br />

above; for individual components, see item 6.)<br />

5.1 INTERLOCKING METHOD, HEIGHT (inches), AND SEAM SEALANT HEIGHT (inches) / SEAM SEALANT (F = Factory HEIGHT (inches) / SEAM SEALANT (F = Factory<br />

Applied; E = Field applied; N = <strong>No</strong>ne) Applied; E = Field applied; N = <strong>No</strong>ne)<br />

Overlapped<br />

Interlocked<br />

Slip Locked<br />

Snap Toge<strong>the</strong>r<br />

1 / N 1 / N<br />

5.2 FASTENING METHOD<br />

Through Fastened (exposed or concealed, specify)<br />

Clip (exposed or concealed, specify)<br />

CONCEALED CONCEALED<br />

6. INDIVIDUAL COMPONENT CONFIGURATION (For components<br />

in item 3.2B above; for panels, see item 5.)<br />

6.1 DIMENSIONS<br />

Weight Per Roof Square (pounds)<br />

Exposure (inches)<br />

Coverage (approx. no. of pieces per square at listed exposure)<br />

6.2 INSTALLATION PROCESSING<br />

Through-Fastened (exposed or concealed, specify)<br />

Kind(s) Of Fastener Required (nails, staples, screws, NA)<br />

Number Of Fasteners Per Piece (number or NA)<br />

Seam Snap-In Or Interlock (specify or NA)<br />

Adhesive/Sealant Required (yes/no)<br />

Support Battens Required (yes/no)<br />

7. MANUFACTURER/PRODUCT DATA<br />

Year Product First Sold 1978 1978<br />

Number of Squares Installed > 100,000 > 100,000<br />

Method Of Distribution (distributors, direct) DISTRIBUTORS, DIRECT DISTRIBUTORS, DIRECT<br />

Number Of Rgional Service Locations 4 4<br />

Licensed Applicator Agreement (yes/no) NO NO<br />

For Sales Information, Contact 800/323-1960 800/323-1960<br />

For Technical Information, Contact 800/323-1960 800/323-1960<br />

8. ASTM E331 WATER INFILTRATION TEST RESULTS NONE NONE<br />

9. ASTM E283 AIR INFILTRATION TEST RESULTS NONE NONE<br />

10. UL FIRE RATINGS FOR ANY SPECIFICATION (per UL 790) NONE NONE<br />

11. FM/UL WIND UPLIFT RATING FOR ANY SPECIFICATION NONE NONE<br />

12. SEE APPENDIX IF CHECKED<br />