Concrete Tile<br />

1. COMPANY NAME MONIER MONIER MONIER MONIER<br />

LIFETILE LIFETILE LIFETILE LIFETILE<br />

2. PRODUCT NAME SANTA FE MISSION SANTA FE SHINGLE CLASSIC MISSION TAOS MISSION<br />

3. TILE TYPE<br />

"S" (SPANISH) MISSION BARREL X X X<br />

DOUBLE "S"<br />

FLAT, SHINGLE- (SLATE-) SHAPE X<br />

FLAT, SHAKE-SHAPE<br />

FLAT, RIBBED<br />

4. TILE DESCRIPTION<br />

Textured (yes or no ) NO YES YES YES<br />

Color Production (surface or through-color) THROUGH-COLOR THROUGH-COLOR THROUGH-COLOR THROUGH-COLOR<br />

Number Of Colors Available<br />

Color Availability (regional/national) NATIONAL NATIONAL NATIONAL NATIONAL<br />

Custom Colors/Blens AvailableE (yes/no) YES YES YES YES<br />

5. ACCESSORY TILES AVAILABLE [e.g., ridge, hip, starter] (yes/no)<br />

6. DIMENSIONS AND COVERAGE<br />

Tile Dimensions (inches x inches) 17 X 12 3/8 17 X 12 3/8 17 X 12 3/8 17 X 12 3/8<br />

Minimum Headlap (inches) 3 3 3 3<br />

Exposure (inches) 14 14 14 14<br />

Pieces Per Roof Square 89 89 89 89<br />

Weight Per Roof Square (pounds) 890 890 890 890<br />

7. SLOPE/UNDERLAYMENT RECOMMENDATIONS<br />

Minimum Slope Recommended For <strong>No</strong>rmal Application (inches per foot) 3:12 3:12 3:12 3:12<br />

Underlayment Recommended In <strong>No</strong>rmal Application 30-LB FELT 30-LB FELT 30-LB FELT 30-LB FELT<br />

Minimum Slope Recommended For Speical Application (inches per foot) < 3:12 < 3:12 < 3:12 < 3:12<br />

Underlayment Recommended In Special Application 2 15-LB FELTS HOT 2 15-LB FELTS HOT 2 15-LB FELTS HOT 2 15-LB FELTS HOT<br />

MOPPED, VERTICAL MOPPED, VERTICAL MOPPED, VERTICAL MOPPED, VERTICAL<br />

COUNTER BATTENS COUNTER BATTENS COUNTER BATTENS COUNTER BATTENS<br />

8A.<br />

RECOMMENDED DECKS AND FASTENING REQUIREMENTS<br />

DECK TYPES<br />

Solid Sheathing<br />

Spaced Sheathing<br />

X X X X<br />

8B. DECK MATERIAL<br />

Plywood/Wood X X X X<br />

Oriented Strand Board<br />

Waferboard<br />

O<strong>the</strong>r (specify)<br />

X X X X<br />

8C. FASTENING REQUIREMENTS<br />

1. Battens Required [at given slope(s), no, or NA]<br />

a. Solid Sheathing < 3:12 AND > 7:12 < 3:12 AND > 7:12 < 3:12 AND > 7:12 < 3:12 AND > 7:12<br />

b. Spaced Sheathing<br />

2. Nailing Requirements, Field Tiles<br />

a. Solid/Spaced Sheathing With Battens [slope(s) or NA]<br />

NA NA NA NA<br />

not required 3:12 TO 5:12 3:12 TO 5:12 3:12 TO 5:12 3:12 TO 5:12<br />

each tile, alternate rows > 5:12 TO 12:12 > 5:12 TO 12:12 > 5:12 TO 12:12 > 5:12 TO 12:12<br />

each tile<br />

b. Solid/Spaced Sheathing Without Battens [slope(s) or NA]<br />

not required<br />

each tile, alternate rows<br />

12:12 AND OVER 12:12 AND OVER 12:12 AND OVER 12:12 AND OVER<br />

each tile 3:12 AND ABOVE 3:12 AND ABOVE 3:12 AND ABOVE 3:12 AND ABOVE<br />

9. YEAR PRODUCT FIRST SOLD<br />

10. NUMBER OF SQUARES INSTALLED<br />

11. DISTRIBUTION<br />

Distributors (number handling product or no) 150 150 150 150<br />

Direct (number of regional service locations or no) NO NO NO NO<br />

12. ACCEPTED BY THE FOLLOWING CODES ICBO (2656), ICBO (2656), ICBO (2656), ICBO (2656),<br />

SBCCI SBCCI SBCCI SBCCI<br />

BOCA BOCA BOCA BOCA<br />

13A FOR SALES INFORMATION, CONTACT B. SESULKA B. SESULKA B. SESULKA B. SESULKA<br />

909/822-4407 909/822-4407 909/822-4407 909/822-4407<br />

13B. FOR TECHNICAL INFORMATION, CONTACT J. VANDEWATER J. VANDEWATER J. VANDEWATER J. VANDEWATER<br />

909/428-4438 909/428-4438 909/428-4438 909/428-4438<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />