Underlayment Sheets<br />

1. COMPANY NAME TAMKO ROOFING TAMKO ROOFING TC MIRADRI<br />

PRODUCTS, INC. PRODUCTS, INC.<br />

2. PRODUCT NAME OR DESCRIPTION NO. 30 ASTM TILE MIRADRI WIP 100<br />

SHAKE UNDERLAYMENT<br />

UNDERLAYMENT<br />

3. PRODUCT CATEGORY<br />

A. Organic Asphalt-Saturated Felt, Unperforated X<br />

B. Organic Asphalt-Saturated Felt, Coated X<br />

C. Aspahtl Fiberglass Felt<br />

D. Special "Ice Shield" Underlayment X<br />

4A. PRODUCT INFORMATION (FOR PRODUCTS IN CATEGORY 3A, 3B, OR 3C)<br />

Type (ASTM standard [specify] or generic) TYPE II (D226)<br />

Available as Sepcialty Underlayment (type, e.g., shake felt) SHAKE FELT TILE UNDERLAYMENT<br />

Sheet Width (inches) 18 36<br />

Size Per Roll (sq. ft.) 180 108<br />

Weight Per Roll (pounds) 47 74<br />

4B. PRODUCT INFORMATION (FOR PRODUCTS IN CATEGORY 3D)<br />

Kind of Sheet(s) (e.g., felts, modified bitumen) MODIFIED BITUMEN<br />

Number Of Ply(ies)/Sheets Comprising Underlayment 1<br />

Waterproofing Medium (e.g., asphalt, modified asphalt) MODIFIED ASPHALT<br />

Application Method (e.g., mechanical, mopped, self-adhered) SELF-ADHERING<br />

Sheet Width (inches) 36<br />

Size Per Roll (sq. ft.) 100/200<br />

Weight Per Roll (pounds) 35/65<br />

5. AVAILABILITY RESTRICTED REGIONALLY (yes/no) NO NO YES<br />

6. RECOMMENDED FOR APPLICATION WITH:<br />

Asphalt Shingles X<br />

Fiber-Cement Roof Components X<br />

Clay Tile X<br />

Concrete Tile X X<br />

Metal Roof Components<br />

Slate X<br />

Wood Shakes/Shingles X<br />

O<strong>the</strong>r (specify)<br />

7. YEAR PRODUCT FIRST SOLD 1996<br />

8. NUMBER OF SQUARES INSTALLED<br />

9. DISTRIBUTION<br />

Distributors (number handling product or no) 200+<br />

Direct (number of regional service locations or no) NO<br />

10. UL-CLASSIFIED PREPARED ROOFING ACCESSORY (yes/no)<br />

COMPLIES WITH:<br />

NO NO YES<br />

11A. ASTM D 224–89 STANDARD SPECIFICATION FOR SMOOTH-SURFACED<br />

ASPHALT ROLL ROOFOING (ORGANIC FELT ) (type or NA)<br />

Type I–Minimum net mass per unit area of roofing, 39.8lb/100 ft<br />

NA NA NA<br />

2<br />

Type II–Minimum net mass per unit area of roofing, 54.6 lb/100 ft 2<br />

Type III–Minimum net mass per unit area of roofing, 51.1lb/100 ft 2<br />

Type IV–Minimum net mass per unit area of roofing, 39.8 lb/100 ft 2<br />

11B. ASTM D 226–95 STANDARD SPECIFICATION FOR ASPHALT-SATURATED<br />

ORGANIC FELT USED IN ROOFING & WATERPROOFING ( type or NA)<br />

Type I–Commonly called <strong>No</strong>. 15 asphalt felt<br />

NA<br />

Type II–Commonly called <strong>No</strong>. 30 asphalt felt<br />

11C. ASTM D 2626–95 STANDARD SPECIFICATION FOR ASPHALT-SATURATED<br />

X X<br />

AND COATED ORGANIC FELT BASE SHEET USED IN ROOFING (yes, no or<br />

NA)<br />

11D. ASTM D 4869–88 (1993) STANDARD SPECIFICATION FOR ASPHALT -<br />

NA NA NA<br />

SATURATED ORGANIC FELT SHINGLE UNDERLAYMENT USED IN ROOFING<br />

(type Type or I–Shingle NA) Underlayment<br />

Type II–Heavy Duty Shingle Underlayment<br />

11E. ASTM D 1970–95 STANDARD SPECIFICATION FOR SELF-ADHERING<br />

NA<br />

POLYMER MODIFIED BITUMINOUS SHEET MATERIAL USED AS STEEP<br />

ROOFING UNDERLAYMENT FOR ICE DAM PROTECTOIN (yes, no, or NA)<br />

NA NA YES<br />

11F. OTHER ASTM SPECIFICATION (specify)<br />

12. ACCEPTED BY THE FOLLOWING CODES<br />

13. FOR SALES INFORMATION, CONTACT: DISTRICT OFFICE DISTRICT OFFICE TC MIRADRI<br />

888/464-7234<br />

FOR TECHNICAL INFORMATION, CONTACT: TECHNICAL SERVICES TECHNICAL SERVICES W. HARVIE<br />

417/624-6644 417/624-6644 888/464-7234<br />

14. SEE APPENDIX IF CHECKED<br />

NA=not applicable<br />