Concrete Tile<br />

1. COMPANY NAME MONIER MONIER MONIER MONIER<br />

LIFETILE LIFETILE LIFETILE LIFETILE<br />

2. PRODUCT NAME VANGUARD FLAT VANGUARD FLAT BERMUDA FLAT BERMUDA FLAT<br />

3. TILE TYPE<br />

"S" (SPANISH) MISSION BARREL<br />

DOUBLE "S"<br />

FLAT, SHINGLE- (SLATE-) SHAPE X X<br />

FLAT, SHAKE-SHAPE X X<br />

FLAT, RIBBED<br />

4. TILE DESCRIPTION<br />

Textured (yes or no ) YES NO YES YES<br />

Color Production (surface or through-color) THROUGH-COLOR THROUGH-COLOR THROUGH-COLOR SURFACE<br />

Number Of Colors Available 10 10 50 1<br />

Color Availability (regional/national) REGIONAL REGIONAL REGIONAL REGIONAL<br />

Custom Colors/Blens AvailableE (yes/no) NO NO YES<br />

5. ACCESSORY TILES AVAILABLE [e.g., ridge, hip, starter] (yes/no) YES YES YES YES<br />

6. DIMENSIONS AND COVERAGE<br />

Tile Dimensions (inches x inches) 16 1/2 X 13 16 1/2 X 13 16 X 9 16 X 9<br />

Minimum Headlap (inches) 2 2<br />

Exposure (inches) 14 14<br />

Pieces Per Roof Square 120 120<br />

Weight Per Roof Square (pounds) 990 990 960 960<br />

7. SLOPE/UNDERLAYMENT RECOMMENDATIONS<br />

Minimum Slope Recommended For <strong>No</strong>rmal Application (inches per foot) 3:12 3:12 3:12 3:12<br />

Underlayment Recommended In <strong>No</strong>rmal Application 43-LB BASE SHEET 43-LB BASE SHEET 30-LB FELT + 90-LB 30-LB FELT + 90-LB<br />

FELT, HOT MOPPED FELT, HOT MOPPED<br />

Minimum Slope Recommended For Speical Application (inches per foot) 2:12 2:12 2:12 2:12<br />

Underlayment Recommended In Special Application 30-LB FELT + 90-LB 30-LB FELT + 90-LB 30-LB FELT + 90-LB 30-LB FELT + 90-LB<br />

FELT, HOT MOPPED FELT, HOT MOPPED FELT, HOT MOPPED FELT, HOT MOPPED<br />

RECOMMENDED DECKS AND FASTENING REQUIREMENTS<br />

8A. DECK TYPES<br />

Solid Sheathing X X X X<br />

Spaced Sheathing<br />

8B. DECK MATERIAL<br />

Plywood/Wood X X X X<br />

Oriented Strand Board<br />

Waferboard<br />

O<strong>the</strong>r (specify)<br />

8C. FASTENING REQUIREMENTS<br />

1. Battens Required [at given slope(s), no, or NA]<br />

a. Solid Sheathing > 7:12 > 7:12 > 7:12 > 7:12<br />

b. Spaced Sheathing<br />

2. Nailing Requirements, Field Tiles<br />

a. Solid/Spaced Sheathing With Battens [slope(s) or NA]<br />

not required<br />

each tile, alternate rows<br />

each tile ALL ALL NA NA<br />

b. Solid/Spaced Sheathing Without Battens [slope(s) or NA]<br />

not required<br />

each tile, alternate rows<br />

each tile ALL ALL NA NA<br />

9. YEAR PRODUCT FIRST SOLD 1988 1988 1958 1958<br />

10. NUMBER OF SQUARES INSTALLED 15,000 15,000 > 3 MILLION > 1 MILLION<br />

11. DISTRIBUTION<br />

Distributors (number handling product or no)<br />

Direct (number of regional service locations or no) 4 4 4 4<br />

12. ACCEPTED BY THE FOLLOWING CODES SBCCI, SBCCI, SBCCI, SBCCI,<br />

METRO-DADE METRO-DADE METRO-DADE METRO-DADE<br />

COUNTY COUNTY COUNTY COUNTY<br />

13A FOR SALES INFORMATION, CONTACT D. BALDWIN D. BALDWIN D. BALDWIN D. BALDWIN<br />

407/338-8200 407/338-8200 407/338-8200 407/338-8200<br />

13B. FOR TECHNICAL INFORMATION, CONTACT R. MOODY R. MOODY R. MOODY R. MOODY<br />

407/338-8200 407/338-8200 407/338-8200 407/338-8200<br />

14. SEE APPENDIX IF CHECKED X X<br />

NA=not applicable<br />