Cowal <strong>Gold</strong> Project – Cyanide Management Plan<br />

6 CYANIDE MONITORING PROGRAMME<br />

In accordance with Consent Condition 8.2(b), the cyanide monitoring programme includes:<br />

• monitoring of CNWAD levels of the aqueous component of the tailings slurry stream at the<br />

discharge point to the tailings dams (Section 6.2);<br />

• monitoring CNWAD levels in the decant water of the tailings dams (Section 6.2);<br />

• an on site laboratory for quickly establishing CNWAD levels in the liquid at the discharge point to<br />

tailings dams and in the decant ponds for monitoring purposes (Section 6.2);<br />

1<br />

• on-line monitoring of HCN (i.e. a form of CNFREE , as discussed in Appendix G of the EIS) at<br />

locations where employees are operating (Section 6.3); and<br />

• a monitoring regime for the detection of cyanide movement beneath and adjacent to the tailings<br />

storages (Section 6.4).<br />

In addition, CNFREE and CNWAD levels will be monitored in the processing plant to provide information<br />

relevant to process control and/or cyanide destruction, as described in Section 6.5.<br />

6.1 REPORTING OF MONITORING<br />

In accordance with Consent Condition 8.2(b) a summary of the cyanide monitoring results will be<br />

provided to EPA, DMR and the Director General for Planning, on a three monthly basis, unless<br />

otherwise agreed by the Director-General. All monitoring results will be included in the AEMR (refer to<br />

Section 9 for reporting obligations).<br />

6.2 CNWAD LEVELS AT THE DISCHARGE POINT TO THE TAILINGS STORAGES AND IN THE<br />

DECANT WATER OF THE TAILINGS STORAGES<br />

Sections 6.2.1 to 6.2.4 describe the monitoring locations and frequency, sample collection, laboratory<br />

analysis, and data management for monitoring CNWAD levels at the discharge point to the tailings<br />

storages and for monitoring CNWAD levels in the decant water of the tailings storages. Section 6.2.5<br />

outlines the review of this monitoring programme.<br />

6.2.1 Monitoring Locations and Frequency<br />

CNWAD levels of the aqueous component of the tailings slurry stream will be monitored at the dischage<br />

point to the tailings storages twice daily (or as otherwise directed by the Director-General for Planning),<br />

in accordance with Consent Condition 8.2(b)(i). In accordance with Consent Condition 8.2(b)(ii),<br />

CNWAD levels in the decant water of the tailings storages will be monitored twice daily (or as otherwise<br />

directed by the Director-General for Planning).<br />

1 CNFREE: Free cyanide, generally includes the cyanide ion (CN - ) and HCN.<br />

HAL-02-07/1/25/CMP-01-Q.DOC 17 BARRICK