8.10 Pump data sheet<br />
Pumping medium:<br />
Temperature: °C<br />
Density: kg/dm 3<br />
Viscosity: mm 2/s<br />
Solids content / Grain size: %/mm<br />
Flow rate: m 3/h<br />
Flow head: m<br />
Plant data Suction side Delivery side<br />
<strong>Pipe</strong> - Ø DN DN<br />
<strong>Pipe</strong> length m m<br />
Ø <strong>and</strong> number <strong>of</strong> bends 45° DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> bends 90° DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> Tees<br />
Direction <strong>of</strong> flow…………… DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> expansions DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> butterfly valves DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> single seat valves<br />
with seat rinsing DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> double seat valves<br />
with seat rinsing<br />
Direction <strong>of</strong> flow…………… DN / DN /<br />
Ø <strong>and</strong> number <strong>of</strong> valve housings<br />
straight through flow DN / DN /<br />
Geodetic heights, pump<br />
towards liquid level m m<br />
Pressure on to<br />
liquid level barG barG<br />
O<strong>the</strong>r pipe installations<br />
O<strong>the</strong>r fittings generating flow resistance<br />
e.g. heat exchanger, filter<br />
(with indication <strong>of</strong> differential pressures<br />
at nominal flow rate) bar at m 3/h bar at m 3/h<br />
Power supply Voltage V Frequency Hz<br />
51<br />
<strong>GEA</strong> Tuchenhagen