A. Meijers et al. / Medical Physics in the Baltic States 7 (2009) 56 - 59<br />

4. Conclusions<br />

Developed tool is easy usable and appropriate for EQSQ<br />

calculation of irregularly shaped fields, which can be<br />

used for manual MU verification. It is easy adjustable<br />

for different machines and beam energies.<br />

Statistically it was determined that optimal number of<br />

vectors for EQSQ calculation is 24. Basic verification of<br />

tool showed that EQSQ can be determined with error<br />

1.32 ± 0.52 %. Such EQSQ error would result in<br />

calculated MU error 0.042 ± 0.021 %.<br />

EQSQ values calculated by developed tool were<br />

compared with values calculated by TPS system with<br />

PBC dose calculation algorithm. Difference between<br />

both results was 1.83 ± 0.85 %.<br />

59<br />

To successfully implement this tool qualitative SMR<br />

data are necessary. If SMR are calculated from PDD<br />

data, it is suggested to measure PDD for 0 × 0 cm field.<br />

For further verification of the tool, it would be<br />

necessary to carry out measurements to determine<br />

whether actual PDD of square field as calculated by the<br />

tool is the same as for given irregularly shaped field.<br />

5. References<br />

1. Khan F. M., The Physics of Radiation Therapy,<br />

Lippincott Williams & Wilkins, Philadelphia, 2003.<br />

p. 511.<br />

2. British Journal of Radiology, 1996, Supplement No.<br />

25.