5.1 Settings and displays possible<br />

Menu displayed text/ Range Increment<br />

option works setting min /max value<br />

1 <strong>NORDAC</strong> SK 1.300/1 to Corresponding to the actual type<br />

SK....../. SK 38.000/3<br />

2 Language:<br />

German German / English<br />

3 Parameter set<br />

1 1 / 4 1<br />

4 Copy parameter<br />

from 2 * 1 / 4 1<br />

5 Accelerat. time 0,05 s in the range from 0,05 to 5 seconds<br />

5.00 sec P1 0,05 / 120 sec 0,1 s in the range from 5 to 10 seconds<br />

0,5 s in the range from 10 to 120 seconds<br />

6 Decelerat. time 0,05 s in the range from 0,05 to 5 seconds<br />

5.00 sec P1 0,05 / 120 sec 0,1 s in the range from 5 to 10 seconds<br />

0,5 s in the range from 10 to 120 seconds<br />

7 Static boost<br />

8 % P1 0 / 30 % 1 %<br />

7.1 Start val. U contr.<br />

8 % P1 0 / 30 % 1 %<br />

8 Dynamic boost<br />

0 % P1 0 / 30 % 1 %<br />

8.1 Limit U control<br />

0 % P1 0 / 30 % 1 %<br />

9 Time dynam. boost<br />

0.0 sec P1 0 / 10 sec. 0,1 s<br />

10 Min. frequency fmin < fmax<br />

0,0 Hz P1 0 / 120 Hz 0,1 Hz<br />

11 Max. frequency fmax > fmin<br />

100,0 Hz P1 0 / 120 Hz 0,1 Hz<br />

>120 Hz if required<br />

12 U/f-character.<br />

50 Hz P1 30 / 999 Hz 1 Hz<br />

13 Setpoint delay<br />

0.00 sec P1 0 / 10 sec. 0,01 s<br />

14 <strong>Frequency</strong> relay<br />

50.5 Hz P1 0 / 120 Hz 0,1 Hz<br />

15 Multifunct. relay<br />

Current P1 Current/<strong>Frequency</strong><br />

16 Funct. frequency<br />

2.0 Hz P1 0 / 120 Hz 0,1 Hz<br />

17 Function current<br />

... A P1 0 / 100 A 0,1 A<br />

18 Sensitivity<br />

15 % P1 5 / 50 % 1 %<br />

19 Ramp respon. time<br />

On P1 On / Off<br />

20 Ramp down<br />

Off P1 On / Off<br />

21 DC braking<br />

Off P1 On / Off<br />

22 Volt. DC braking<br />

0 % P1 0 / 30 % 1 %<br />

23 Time DC braking<br />

0.0 sec P1 0 / 10 sec. 0,1 s<br />

24 Contr. reac. curr.<br />

Off On / Off<br />

25 Refer. reac. curr.<br />

1,0 A P1 0 / 99,9 A 0,1 A<br />

26 Fault history 1 last 5 error<br />

Excess temp.motor 2 messages<br />

27 Actual fault up to 20 different<br />

No fault 0 errors<br />

28 cosphi Iw/A Ib/A displayed operating value<br />

1,0 0,0 0,0 (status indicator)<br />

29 F/Hz P/kW cos displayed operating value<br />

0,0 0,0 1,0 (status indicator) 13