10.0 Mains filter<br />

Normal version contains:<br />

- Line choke | to protect the inverter<br />

- Capacitors |---> against normal mains<br />

- Varistors | voltage peaks<br />

Special cases:<br />

- Installation of a standard mains filter ---> protects against high-frequency voltage peaks<br />

(data on request) (e.g. in the case of power-factor correction systems, welding equipment etc.)<br />

10.1 Radio interference suppression<br />

RFI suppression is possible if required.<br />

Reducing the emitted interference to the value of limit value class B in accordance with VDE 0871:<br />

- with mains-circuit coupling ---> by use of standard RFI suppression filters<br />

- with emitted interference ---> by use of a screened cable or<br />

of the motor supply line lay in earthed heavy-gauge steel conduit<br />

a) Arrange earth connection (PE) a)<br />

- ensure very low resistance<br />

- arrange connection/transition with<br />

large cross-section<br />

Screening<br />

- bring as close as possible to the<br />

inverter and the motor (< 0,2 m)<br />

- do not interrupt<br />

- connect on both sides to earth (PE)<br />

If (a) is not sufficient to suppress<br />

interference --> try b)<br />

b) As a), but in more advanced form, with b)<br />

line compensation choke or standard output<br />

filter with higher damping<br />

(chokes and filters available on request<br />

at extra charge)<br />