OPERATING INSTRUCTIONS NORDAC Frequency Inverters
OPERATING INSTRUCTIONS NORDAC Frequency Inverters
OPERATING INSTRUCTIONS NORDAC Frequency Inverters
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
4.0 Connection<br />
4.1 Power section<br />
4.1.1 Typ SK 1.300/1 - SK 2.400/1<br />
Connection for mains, braking chopper and motor - via screw-type push-lock terminal strips on the lower output stage<br />
board<br />
Maximum line cross-sectional area - 2,5 mm 2<br />
Keep earth connection (PE) at very low ohms.<br />
<strong>NORDAC</strong> SK 1.300/1...SK 2.400/1 - Please mind the line lengths!<br />
Mains Braking chopper Motor<br />
SK 3/350/22 +<br />
SK 6/350/64<br />
4.1.2 Typ SK 1.300/3 - SK 38.000/3<br />
* if required<br />
- Cf. point 10.3<br />
Connection for mains, braking chopper and motor SK 1300/3 to SK 5900/3<br />
Maximum line cross-sectional area - 2,5 mm 2 via screw-type push-lock terminal strip on the<br />
Keep earth connection (PE) at very low ohms lower output stage board<br />
SK 7.500/3 and 10.000/3<br />
<strong>NORDAC</strong> SK 1.300/3...SK 38.000/3 - 4,0 mm 2 via screw-type terminal strip on the line and output choke<br />
Mains Braking chopper Motor<br />
SK 3/600/64...<br />
SK 24/600/720<br />
SK 40/600 ... SK 130/600<br />
(-) (+) (PE)<br />
SK 15.000/3 to SK 30.000/3<br />
- 10 mm 2 via screw-type terminal strip on the line and output choke<br />
SK 38.000/3<br />
- 16 mm 2 via screw-type terminal strip on the line and output choke<br />
* if required - Please mind the line lengths!<br />
- Cf. point 10.3<br />
braking resistance<br />
4.1.3 Additional measures (compare point 10.2, 10.3 and 10.4)<br />
Types SK 1.300/1 to SK 2.400/1 and SK 1.300/3 to SK 38.000/3<br />
4<br />
Also for braking chopper connection (recommended < 10m)<br />
230 / 240 V<br />
50 / 60 Hz<br />
auxiliary voltage