4.4 Nominal carcass dimensions<br />
In case of the fabrication of doors, all dimensions conform to<br />
the nominal carcass dimensions, DIN 18100, and to the di-<br />
mensional co-ordination in building construction, DIN 4172.<br />
1<br />
2<br />
RR<br />
Clear opening width<br />
B = RR + (2x5) mm<br />
RR<br />
Nominal<br />
dimension<br />
Nominal<br />
B<br />
dimension B<br />
Height from floor level (OFF) to<br />
lower edge of the lintel or ceiling<br />
OFF<br />
Reference point for the height:<br />
Nominal dimension H<br />
The reference marker is a marking, which is exactly 1 m<br />
above the surface of the finished floor (OFF) and it shall<br />
not be more than 10 m away from the place of installation.<br />
There must be a reference marker in every storey.<br />
Final measurements and determination of the real building situation<br />
ORF<br />
The data apply to to masonries with with standard standard<br />
joint widths and and standard stone stone formats. formats.<br />
In In case of of jointless building building components: components:<br />
structural<br />
structural<br />
dimension<br />
dimension<br />
= RR<br />
= RR<br />
The fabricator of the carcass is responsible for observing<br />
these dimensions and for the marking of the reference mark-<br />
er (1 m above the surface floor).<br />
WITHIN THE QKE · WWW.GKFP.DE<br />
1<br />
2<br />
3<br />
3<br />
Fig. 6: Nominal carcass dimensions, doors<br />
2<br />
ORF OFF<br />
Height from floor level (OFF) to<br />
lower edge of the lintel or ceiling.<br />
1<br />
Clear opening width<br />
Reference marker<br />
OFF = floor level<br />
OFR = raw floor level<br />
RR = nominal carcass dimension<br />
3<br />
100<br />
It is marked in every room near to doors and windows. By<br />
means of a hose level, a land leveler or a laser, the reference<br />
marker can be projected onto the desired position.<br />
Chapter<br />
4<br />
21