6.2.4 Couplings<br />
For the safe transfer of the loads into the building, the rein-<br />
forcements used for the stiffener in case of element cou-<br />
plings, must be fastened at the building.<br />
Continuous steel/concrete<br />
reinforcement with connection<br />
to the building, on<br />
top and at the bottom<br />
Movable bearing<br />
with elongated hole<br />
Thrust bearing or<br />
spreader plate<br />
Movable bearing<br />
Spacing block<br />
Window width Elongation l (mm) in case of ± 30°C<br />
(cm) with = <strong>70</strong> · 10 PVC-U -6 /K with = 42 · 10 window -6 /K<br />
150 ± 3,15 ± 1,9<br />
250 ± 5,25 ± 3,2<br />
350 ± 7,35 ± 4,4<br />
450 ± 9,45 ± 5,7<br />
WITHIN THE QKE · WWW.GKFP.DE<br />
The installation<br />
Take into account the fact that the reinforcements may nev-<br />
er be clamped securely but can take part of the movements<br />
occuring from the construction work because of the use of a<br />
movable bearing according to fig. 21.<br />
Movable bearing<br />
Fastening of the angle fixing<br />
brackets in element direction<br />
In case of great element widths or heights, an expansion<br />
joint is to be mounted according to the manufacturer’s<br />
instruction, to be able to take both the horizontal and<br />
the vertical expansion of the profiles (fig. 22).<br />
Chart 3: Standard values for thermal elongation of<br />
PVC-profiles and windows<br />
Fig. 21: Element couplings<br />
Fastening of the angle fixing<br />
brackets vertical (90°) to element<br />
direction<br />
Fig. 22: Expansion joint<br />
Chapter<br />
6<br />
39