[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Main Sub<br />
code code<br />
26 43 Side void amount setting<br />
(SIDE VOID)<br />
62 Energy-save mode copy<br />
lamp setting (C-LAMP E-S)<br />
30 01 Paper sensor status display<br />
(P-SENSOR)<br />
Contents Details of function/operation<br />
[Function]<br />
When this test command is executed, the currently set code of the side void quantity is displayed (initial<br />
display), and the set data are saved. (Setting range: 0 – <strong>10</strong>, Default: 4 (= One side 2.0mm))<br />
9<br />
Code Setting Remark<br />
0 0 mm<br />
1 0.5 mm<br />
2 1.0 mm<br />
3 1.5 mm<br />
4 2.0 mm Default<br />
5 2.5 mm<br />
6 3.0 mm<br />
7 3.5 mm<br />
8 4.0 mm<br />
9 4.5 mm<br />
<strong>10</strong> 5.5 mm<br />
∗ When the adjustment value is increased by 1, the side void is changed as follows:<br />
Side void adjustment: The side void is increased by 0.5mm. (The side void of “Set value x 0.5mm”<br />
is made.)<br />
[Operation]<br />
1) Initial display 2) [<strong>10</strong>KEY] 3) [ENTER/START]<br />
26-43 SIDE VOID<br />
4( 0-<strong>10</strong>)<br />
[Function]<br />
Used to set half-ON /OFF of the copy lamp in the pre-heat mode.<br />
When this test command is executed, the current set code number is displayed. Enter the desired<br />
code number and press [ENTER/START] key to save the setting.<br />
[Operation]<br />
The operation is similar to test command 21-01.<br />
[Function]<br />
The paper sensor status is displayed on the LCD.<br />
∗ Since the manual paper feed sensor is a single bypass sensor, its status is not displayed.<br />
∗ The width sensor is available only in the FAX models.<br />
[Operation]<br />
26-43 SIDE VOID<br />
5( 0-<strong>10</strong>)<br />
Code number Setting Display item Remark<br />
0 Copy lamp OFF OFF<br />
1 Copy lamp half-ON ON Default<br />
Sensor Display item Remark<br />
Paper exit sensor POD<br />
No. 1 tray paper width sensor PD1<br />
Paper entry sensor PPD1<br />
Duplex sensor PPD2<br />
No. 2 tray paper feed sensor PPD3<br />
New drum cartridge sensor DRST<br />
1) Initial display 2) When sensor ON<br />
30-01 P-SENSOR 30-01 POD PD1 PD2<br />
PPD1 PPD2 PPD3 DRST<br />
AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 15<br />
26-43 SIDE VOID<br />
5( 0-<strong>10</strong>)