[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Main Sub<br />
code code<br />
63 01 Shading check (SHADING<br />
CHK)<br />
Contents Details of function/operation<br />
02 Black level automatic<br />
correction (BLACK LEVEL)<br />
[Function]<br />
Used to display the detection level of white plate for shading.<br />
When [ENTER/START] key is pressed, the mirror base unit moves to the white plate for shading and<br />
the copy lamp is lighted.<br />
When the light quantity is stabilized, revision is made for every second, and the level of one pixel at<br />
the center of CCD which is not corrected is detected and the value is displayed in decimal values on<br />
the LCD. (3 digits)<br />
[Operation]<br />
1) Initial display<br />
63-01 SHADING CHK<br />
EXECUTING... 000<br />
[Function]<br />
Used to acquire the black level target value used for the black level adjustment of white balance.<br />
When this test command is executed, the current correction value is displayed in 3 digits of 12bit<br />
hexadecimal number.<br />
Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the density<br />
<strong>10</strong> (black side) comes on the left side and that the chart is upside down at the center of the plate<br />
left center.<br />
When [ENTER/START] key is pressed, the mirror base unit scans the chart and calculates the correction<br />
value.<br />
After completion of correction, the corrected value is displayed on the LCD.<br />
∗ Default: 0<br />
∗ If the value is set to the default, operation is made with 0x60.<br />
[Operation]<br />
1) Initial display<br />
63-02 BLACK LEVEL<br />
000<br />
Chart back surface<br />
AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 30<br />
<strong>10</strong><br />
2) [ENTER/START] Correction start<br />
63-02 BLACK LEVEL<br />
EXECUTING...<br />
<br />
After canceling, the machine goes into the sub code entry<br />
standby mode.<br />
THE JOB IS BEING<br />
CANCELED.<br />
3) After execution<br />
63-02 BLACK LEVEL<br />
*** OK<br />
3) In case of an error<br />
63-02 BLACK LEVEL<br />
*** ERR