[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
[10] TEST COMMAND, TROUBLE CODES - OlsonBros
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Main Sub<br />
code code<br />
8 01 Developing bias output<br />
(DVLP BIAS SET.)<br />
02 Main charger output (Grid<br />
HIGH) (MHV(H) SET.)<br />
03 Main charger output (Grid<br />
LOW) (MHV(L) SET.)<br />
06 Transfer charger output<br />
(THV SET.)<br />
9 01 Duplex motor normal<br />
rotation check (DPLX ROT.)<br />
(Enabled when Duplex<br />
setting is ON)<br />
Contents Details of function/operation<br />
02 Duplex motor reverse<br />
rotation check (DPLX<br />
ROT.REV.) (Enabled when<br />
Duplex setting is ON)<br />
04 Duplex motor rotating speed<br />
adjustment (DPLX<br />
ROT.SPEED) (Enabled<br />
when Duplex setting is ON)<br />
[Function]<br />
When [ENTER/START] key is pressed, the developing bias signal is turned ON for 30sec.<br />
When, however, an actual output value is measured, use test command 25-01.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
08-01 DVLP BIAS SET.<br />
EXECUTING...<br />
[Function]<br />
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage<br />
HIGH move.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
08-02 MHV(H) SET.<br />
EXECUTING...<br />
[Function]<br />
When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage<br />
LOW move.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
08-03 MHV(L) SET.<br />
EXECUTING...<br />
[Function]<br />
When [ENTER/START] key is pressed, the transfer charger is outputted for 30sec.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
08-03 THV SET.<br />
EXECUTING...<br />
[Function]<br />
Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for<br />
30sec.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
09-01 DPLX ROT.<br />
EXECUTING...<br />
[Function]<br />
Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.<br />
After completion of this process, the machine goes into the sub code entry standby mode.<br />
[Operation]<br />
1) Initial display<br />
09-02 DPLX ROT.REV.<br />
EXECUTING...<br />
[Function]<br />
When this Test Command is executed, the currently set value is displayed.<br />
Enter the adjustment value with [<strong>10</strong>KEY] and press [START] key. The entered value is stored and the<br />
machine goes into the sub code entry standby mode. The greater the set value is, the higher the<br />
speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 8)<br />
[Operation]<br />
1) Initial display 2) [<strong>10</strong>KEY] 3) [ENTER/START]<br />
09-04 DPLX ROT.SPEED<br />
8( 1-13)<br />
09-04 DPLX ROT.SPEED<br />
7( 1-13)<br />
AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 7<br />
09-04 DPLX ROT.SPEED<br />
7( 1-13)