Main Sub<br />

code code<br />

8 01 Developing bias output<br />

(DVLP BIAS SET.)<br />

02 Main charger output (Grid<br />

HIGH) (MHV(H) SET.)<br />

03 Main charger output (Grid<br />

LOW) (MHV(L) SET.)<br />

06 Transfer charger output<br />

(THV SET.)<br />

9 01 Duplex motor normal<br />

rotation check (DPLX ROT.)<br />

(Enabled when Duplex<br />

setting is ON)<br />

Contents Details of function/operation<br />

02 Duplex motor reverse<br />

rotation check (DPLX<br />

ROT.REV.) (Enabled when<br />

Duplex setting is ON)<br />

04 Duplex motor rotating speed<br />

adjustment (DPLX<br />

ROT.SPEED) (Enabled<br />

when Duplex setting is ON)<br />

[Function]<br />

When [ENTER/START] key is pressed, the developing bias signal is turned ON for 30sec.<br />

When, however, an actual output value is measured, use test command 25-01.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

08-01 DVLP BIAS SET.<br />

EXECUTING...<br />

[Function]<br />

When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage<br />

HIGH move.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

08-02 MHV(H) SET.<br />

EXECUTING...<br />

[Function]<br />

When [ENTER/START] key is pressed, the main charger is outputted for 30sec in the grid voltage<br />

LOW move.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

08-03 MHV(L) SET.<br />

EXECUTING...<br />

[Function]<br />

When [ENTER/START] key is pressed, the transfer charger is outputted for 30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

08-03 THV SET.<br />

EXECUTING...<br />

[Function]<br />

Use the duplex motor Bios to drive the duplex motor in the normal direction (paper exit direction) for<br />

30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

09-01 DPLX ROT.<br />

EXECUTING...<br />

[Function]<br />

Use the duplex motor Bios to drive the duplex motor in the reverse direction for 30sec.<br />

After completion of this process, the machine goes into the sub code entry standby mode.<br />

[Operation]<br />

1) Initial display<br />

09-02 DPLX ROT.REV.<br />

EXECUTING...<br />

[Function]<br />

When this Test Command is executed, the currently set value is displayed.<br />

Enter the adjustment value with [<strong>10</strong>KEY] and press [START] key. The entered value is stored and the<br />

machine goes into the sub code entry standby mode. The greater the set value is, the higher the<br />

speed is. The smaller the set value is, the lower the speed is. (Setting range: 1 - 13, Default: 8)<br />

[Operation]<br />

1) Initial display 2) [<strong>10</strong>KEY] 3) [ENTER/START]<br />

09-04 DPLX ROT.SPEED<br />

8( 1-13)<br />

09-04 DPLX ROT.SPEED<br />

7( 1-13)<br />

AR-168S/168D <strong>TEST</strong> <strong>COMMAND</strong>, <strong>TROUBLE</strong> <strong>CODES</strong> <strong>10</strong> - 7<br />

09-04 DPLX ROT.SPEED<br />

7( 1-13)